EIR203 1308qsg-2/2
© 2008 by B&B Electronics. All rights reserved.
International Headquarters:
707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104
www.bb-elec.com [email protected] [email protected]
European Headquarters:
Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445
www.bb-europe.com [email protected] [email protected]
B&B
ELECTRONICS
QUICK START GUIDE
Attach Fiber Optic Cable
(if equipped)
Warning: Work Safe – Fiber Optic
equipped models are Class I
Laser/LED devices. To avoid causing
serious damage to your eyes, DO NOT
STARE DIRECTLY INTO THE LIGHT.
1. Slider
Guide
2. Slider
Ridges
3. Slider
Installation Complete
1. When the network cables are attached and power
is applied, installation is complete.
2. The switch will automatically discover network
devices, populate its MAC address table, and
pass traffic to the appropriate ports.
Mechanical Diagram
Fiber Optic Cable Information
Mode and Distance
Type
Wavelength
Multi-mode (2 km)
62.5/125 µm
1310 nm
Single-mode (15 km)
9/125 µm
1310 nm
Single-mode (40 km)
9/125 µm
1310 nm
Single-mode (80 km)
9/125 µm
1550 nm
Output Power
RCVR Sensitivity
Multi-mode (2 km)
-19 to -14 dBm
≤
-32 dBm
Single-mode (15 km)
-15 to -8 dBm
≤
-32 dBm
Single-mode (40 km)
-5 to 0 dBm
≤
-34 dBm
Single-mode (80 km)
-5 to 0 dBm
≤
-34 dBm
1.
Ensure your fiber optic cable is terminated with
the correct connector type. EIR203 switches use
SC or ST connectors.
2.
Fiber optic type for each port is located on the
product’s side label. When connecting the cable
to the switch, be sure to line up the slider guide
on the cable and switch connectors.
3.
Connect the fiber optic transmitter to the
downstream device’s receiver and vice-versa.