Observed Problem
Possible Cause
Solution
Failure to cut clamp
tail (cont.)
Cut-off link jam.
De-energize system for safety. Contact BAND-IT.
Cut-off Cylinder arm not connected
properly.
Verify Cut-off Cylinder arm is connected properly,
with pins fully inserted.
Knife and pins un-lubricated.
Lubricate.
Loose head mounting screws.
Tighten all mounting screws.
Cut-off cylinder actuation timing is less
than recommended.
Actuate cutoff cylinder for at least recommended
timing.
Locking dimple too
shallow.
Punch pressure too low.
Check pressure setting. Check air tubing and
fittings for obstructions.
Clamp buckle located above void or
opening.
Be sure to locate buckle on fully supported
surface.
Object being clamped is hand-held.
Small light-weight objects clamped must be
properly held in place in a fixture.
Object being clamped is soft with thick
wall.
Adjust the Punch pressure higher and verify
dimple depth. Be sure that object clamped is held
in place and locked down in fixture. Adjust
tension and hold force settings if necessary.
Punch cylinder actuation timing is less
than recommended.
Actuate punch cylinder for at least recommended
timing.
Trigger mechanism did not fire properly.
Verify that air source and fittings are pressurized,
unobstructed, and not leaking. Verify that the
trigger cylinder can extend and retract without
obstruction. Grease the trigger clevis pin.
Locking dimple too
deep.
Punch cylinder pressure too high.
Adjust to a lower pressure.
Head sensors not
activating
Sensor Damaged
Place metallic object against sensor and verify the
sensor activates on the HMI screen.