560 M1 06 C
19-03-2014
Page 2
1. MOUNTING
Verify tank flanges compatibility with MAGTOP flanges.
Install level indicator on tank side.
Do not forget to set seals (not furnished).
It is highly suggested to set insulation valves, between tank and level indicator, in
order to be able to remove the float in case of jamming.
Insert the float by removing union 7.
H is indicating float top.
During installation, bi-colours flaps may not be goodly set.
They will get right position on float movement.
They must be red when float is going up, and yellow when float is going down.
In case of bad level reading, flaps rule can be turned around the tube by unlocking
fixing collars.
After re-positioning, lock smoothly collars to avoid damaging this rule.
MAGTOP can be equipped with different options which are:
- Graduated ruler, done with agreement, with requested measure unit
(cm, % or volume)
- Continuous level output rule with potentiometric or 4-20mA analogic output (RTM)
- Level switches: BRK-60 MAG ; BRT-60 MAG
(To set a level switches or other options, see specific starting up notice.)
2. STARTING UP
It is suggested to install level indicator on atmospheric pressure, to avoid to quick
up float movement, which may damage it.
On magnet passage, flaps turn of 180° passing from yellow to red.
Exact level is indicting by flaps which turned only of 90°.
Indicator drain has to be done by unscrewing nut 9.
3. MAINTENANCE
For wast liquids with particles, float might be stopped. Drain level indicator and
tank to eliminate dusts. If the float is steal keep stopped, dismount the MAGTOP
for full cleaning.
4. TECHNICAL FEATURES
MAGTOP 801
Process connection:
PVC flange,
ND 25 or ND 32
(PN 10)
Material:
PVC
Max. temperature of fluid:
50°C
Pressure /MAGTOP:
6 bar at 20°C as a maximum
Density:
1
MAGTOP 803
Process connection:
PPH flange,
ND 25 or DN 32
(PN 10)
Material:
PPH
Max. temperature of fluid:
90°C
Pressure /MAGTOP:
6 bar at 20°C as a maximum
Density:
1
MAGTOP 806
Process connection:
PPH steel reinforced flanges,
ND 25 or DN 32
(PN 10)
Material:
PVDF
Max. temperature of fluid:
110°C
Pressure /MAGTOP:
6 bar at 20°C as a maximum
Density:
1
It.
Description
1
PVC, PPh or PVDF
guiding tube Ø 63
2
MAKROLON magnet ruler
3
PVC, PPh or PVDF float
4
Supplementary support
5
PVC or PPH steel reinforced
flanges, ND 25 or ND 32
6
PVC, PPh or PVDF
sealing surface
7
Magnet ruler fixing collar,
stainless steel 304
8
Union (3 pieces) for maintenance
9
Drain tap
10
Draining valve (option)
11
Level switches
(option)