background image

02-03-2015

584 M0 01 F

Page 2

MOUNTING

The indicator exceeds very widely the summit of the tank, it is necessary to make sure that there is enough space to take it up.
The indicator is linked to the tank by DN65 flange connection (FS4 model) or 2’’ threated connection (FS4 Fût model)  

For contact adding or any option, please refer to owner’s manual of those device .The FS4 indicator is ready since its mounting
on the tank. The float follows level raising and the colored indicator shows level position on upper part of the device. To avoid
any overpressure which could prevent the float to go up, two little holes are located under the fixating flange.

MAINTENANCE

FS4 is a robust level indicator; it does not require specific maintenance. From time to time, clean the float and back face of tube. 

TECHNICAL FEATURES

Float:

PPH or PVC

Stem:

PPH or PVC

Guiding tube:

PPH or PVC

Indicator:

PPH/PVC or PVC

Temperature maxima

PVC: 60 °C 
PPH: 80 °C 

Maximal pressure:

Atmospheric

OPTION:

Level switches BSM 501 
or BRK 60/32

Standard model 

Maximal height:

3000 mm, depending of fluid specific weight 

Mounting:

Loose flange ND 65, in PPH or PVC 

For drums 

Maximal height:

1000 mm, depending of fluid specific weight 

Mounting:

Thread 2” G, PVC or PPH 
Metric buttress thread, PVC or PPH

(other on request)

Reviews: