Top tank level indicator
Top tank level indicator
FS4
02-03-2015
584 M1 01 F
MES
584-01
INSTRUCTIONS MANUAL
Top kank level indicator
FS4
CAUTIONS
• Installing and operating the unit FS4 must be done outside of any magnetic field.
• Any iron device must be at least at 10 cm as a minimum.
• Use non magnetic connection
(Brass, Stainless Steel or plastic)
.
• Verify the chemical compatibility between the fluid and FS4 materials.
• Pressure inside the tank and indicator, must be at 1 bar as a maximum or less.
PRINCIPLE
• This indicator allows a direct level reading, on time, on any liquid level
(respecting chemical resistances)
even when tank is opaque.
• Assembly is done above the tank. Float and index with magnet, are fixed on a stem.
• When indicator is on the tank, the float follows the liquid level increases, so does the index.
• Index with magnet can actuate one or more, BSM 501 level switches.
• A graduated ruler (option) fit the indicator tube for a quantified reading.