Bambi VT75 Operator'S Handbook Manual Download Page 28

26

Motor / Pump Parts: 

VT250 / VT250D / VTS250 / VTS250D

Ref No.

Description

Part no.

1

Motor VT250

BPB0995

2a

Outlet connector

BPB0614

2b

Outlet connector

BPB0654

3

Block fixing

BPB0665

4

Block motor side

BPB0666

5

Block screw

BPB0667

6

Block bearing

BPB0668

7

Short spacer

BPB0669

8

Con rod

BPB0670

9

Con rod bearing

BPB0671

10

Eccentric

BPB0672

11

Large spacer

BPB0673

12

Capacitor

BPB0701

13

Block O ring

BPB0674

14

Eccentric nut

BPB0984

15

Block fan side

BPB0675

16

Stud bolt

BPB0676

17

Washer

BPB0677

18

M16 nut

BPB0678

19

VT250 Outer fan cover

BPB0991

20

VT250 fan ring

BPB0990

21

Fan cover fixing

BPB0706

22

VT250 Right hand fan

BPB0988

23

VT250 Inner fan cover

BPB0987

24

Piston seal

BPB0623

25

Top washer

BPB0693

26

Top washer screw

BPB0692

27

Cylinder

BPB0690

28

Valve plate gasket

BPB0621

29

Inlet valve strip

BPB0685

30

Outlet valve strip

BPB0685

31

Valve plate nut

BPB0683

32

Cylinder head gasket

BPB0620

33

Inlet filter

BPB0682

34

Cylinder head

BPB0681

35

Cylinder head bolt

BPB0680

36

Valve plate washer

BPB0684

37

Valve plate

BPB0686

38

Valve plate bolt

BPB0687

39

Cyinder bolt

BPB0688

40

Cylinder O ring

BPB0691

41

VT250 Left hand fan

BPB0989

42

90° connecting pipe

BPB0993

43

Straight pipe

BPB0994

44

Tee piece

BPB0992

45

Connecting pipe nut

BPB0986

46

Connecting pipe olive

BPB0985

1

5

7

8

9

10

15

16

17

18

19

20

21

22

23

24

27

28

29

30

31

33

34

35

36

37

39

2a

4

26

25

38

41

42

43

40

6

11

13

14

12

32

44

3

46

45

2b

7

17

6

Summary of Contents for VT75

Page 1: ...RS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT Tel 44 0 121 322 2299 Fax 44 0 121 322 2297 Email sales bambi air co uk www bambi air co uk VT75 VT75D VTS75 VTS75D VT150 VT150D VTS150 VTS150...

Page 2: ...anical or personnel hazards and will invalidate your warranty Bambi reserves the right to modify the contents of this operating booklet without notice and the information is in no way binding on the c...

Page 3: ...d bearing capacity Allow access for maintenance all around the compressor Site in a dry area avoiding damp or humid conditions The site must be dust free well ventilated and have a cool ambient temper...

Page 4: ...fit before use Attach the condensate bottle mounting bracket to the front panel of the compressor using the 2 plastic clips provided These are a simple push fit Slide the condensate bottle into the mo...

Page 5: ...al start system to reduce electrical loading You will notice one motor starting a few seconds after the other single phase only This is normal As air is used the pressure drops and the motor will rest...

Page 6: ...ut using excessive force Fig 6 Pressure relief valve positions 6 Operation Dryer Models When equipped with an air dryer unit the compressor will automatically dry the compressed air before it is store...

Page 7: ...follow the procedure below Models VT75 75D VT150 150D VT200 200D VT250 250D Switch off at the pressure switch see Fig 2 Allow 50 minutes for the motor to cool down then switch back on at the pressure...

Page 8: ...ver in place and remove the end covers Remove the bolts holding the top cover in place Gently lift up the top housing Note Do not use excessive force as this will strain the electrical and air connect...

Page 9: ...0 240 380 415 Frequency Hz 50 Amps Single phase 3 phase 6 8 2 9 Displacement l min 175 VT 2 0Hp Pump Specification Motor Kw Hp 1 5 2 0 Voltage Single phase 3 phase 220 240 380 415 Frequency Hz 50 Amps...

Page 10: ...n tube BPB0203 10 Crankcase mounting bracket BPB0347 11 20mm rubber mounting BPB0273 12 Drain valve tap BPB0281 13 3 8 x 10mm tube elbow BPB0277 14 Red nylon drain tube BPB0284 15 50mm tank pressure g...

Page 11: ...0560 16 Aftercooler mounting bracket BPB0557 17 40mm mounting rubber BPB0272 18 Motor mounting bracket BPB0321 19 Crankcase mounting bracket BPB0347 20 20mm mounting rubber BPB0273 21 Drain valve tap...

Page 12: ...BPB0203 10 20mm mounting rubber BPB0273 11 Crankcase mounting bracket BPB0347 12 3 8 drain tap BPB0281 13a 3 8 x 10mm tube elbow VT200 BPB0280 13b 3 8 x 10mm tube elbow VT150 BPB0277 14 0 6m drain tu...

Page 13: ...a Motor mounting bracket VT150D BPB0321 17b Motor mounting bracket VT200D BPB0516 18 Crankcase mounting bracket VT150D BPB0347 19 20mm Rubber mounting BPB0273 20 3 8 Drain tap BPB0281 21 0 6m 10mm Dra...

Page 14: ...24 1 8BSPF x 6mm elbow BPB0278 25 Inspection plug seal BPB0502 26 M8 x 20 Hex screw BPB0265 27 1 4BSP M F F tee BPB1109 28 M6 x 25 washer BPB0121 29 M8 nut BPB0161 30 1 4BSP x 10mm elbow BPB0276 31 1B...

Page 15: ...13 1 5 7 8 9 10 15 16 17 18 19 20 21 22 23 24 27 28 29 30 31 33 34 35 36 37 39 2 4 26 25 38 41 42 43 40 6 11 13 14 12 32 44 3 46 47 48 45 49 51 50 52 53 54 55 56...

Page 16: ...ube elbow BPB0276 20 On off valve BPB1079 21 End panel BPB0538 22 1 4BSP x 63mm 0 160 gauge BPB0748 14 36 3 8BSPF x 10mm tube connector BPB0275 37 3 8BSPM non return valve BPB0822 38 3 8BSP M F plated...

Page 17: ...1 5 7 8 9 10 15 16 17 18 19 20 21 22 23 24 27 28 29 30 31 33 34 35 36 37 39 2 4 26 25 38 41 42 43 40 6 11 13 14 12 32 44 3 45 49 50 51 53 54 55 56 57 59 58 61 62 63 60 52 64 66 67 68 65 69 70 46 47 4...

Page 18: ...081 14 3 8BSP M F F tee BPB0802 15 Safety valve BPB1084 16 1 4BSPT M F elbow BPB1139 17 Pressure switch BPB0550 18 1 4BSPT x 1 4BSPMT adaptor BPB1078 19 3 8BSP x 3 8BSP adaptor BPB0283 20 On Off valve...

Page 19: ...BPB0802 23 Pressure gauge BPB1081 24 Safety valve BPB1084 25 1 4BSPT M F elbow BPB1139 26 Pressure gauge BPB0657 27 Pressure switch BPB0550 28 3 8BSP x 3 8BSP adaptor BPB0283 29 On Off valve BPB1079...

Page 20: ...mm Rubber mount BPB0273 24 M8 Flanged nut BPB0130 25 M8 Hex full nut BPB0161 26 40mm Rubber mount BPB0272 27 Cabinet LH panel BPB0351 28 1 8BSPF x 6mm elbow BPB0278 29 400mm Delivery pipe BPB0508 30 3...

Page 21: ...19 1 5 7 8 9 10 15 16 17 18 19 20 21 22 23 24 27 28 29 30 31 33 34 35 36 37 39 2 4 26 25 38 41 42 43 40 6 11 13 14 12 32 44 3 46 47 48 45 49 51 50 52 53...

Page 22: ...33 Coalescing filter manual drain BPB0983 34 400mm Delivery pipe BPB0508 35 600mm Delivery pipe BPB0798 36 3 8BSP M F elbow BPB0282 37 3 8BSP Bulkhead connector BPB0749 38 Coalescing filter manual dra...

Page 23: ...21 73...

Page 24: ...ube BPB0199 14 3 8 x 1 4 Hose tail BPB0652 15 Drain valve BPB0281 16 Solenoid c w cable BPB0545 17 1 8 x 6mm Push fitting BPB0154 18 Crankcase mounting bracket VT300 BPB0347 19 20mm Rubber mounting BP...

Page 25: ...B0655 27 1 4 x 3 8 Adaptor BPB0591 28 Dryer mounting clamp BPB0503 29 Purge tank BPB0484 30 Purge tank bleed pipe BPB0775 31 Dryer assembly BPB0548 32 1 4 x 10mm Swivel elbow BPB0276 33 Solenoid valve...

Page 26: ...BPB0679 19 Fan cowling BPB0626 20 Cylinder head bolt BPB0680 21 Cylinder head BPB0681 22 Intake filter BPB0682 23 Cylinder head gasket BPB0620 24 Valve plate nut BPB0683 25 Valve plate washer BPB0684...

Page 27: ...r BPB0703 19 Fan BPB0704 20 M16 Fan nut BPB0679 21 Fan ring BPB0705 22 Fan cover fixing BPB0706 23 Cylinder head bolt BPB0680 24 Cylinder head BPB0681 25 Intake filter BPB0682 26 Cylinder head gasket...

Page 28: ...t hand fan BPB0988 23 VT250 Inner fan cover BPB0987 24 Piston seal BPB0623 25 Top washer BPB0693 26 Top washer screw BPB0692 27 Cylinder BPB0690 28 Valve plate gasket BPB0621 29 Inlet valve strip BPB0...

Page 29: ...s SINGLE PHASE VT K Live Neutral Earth KKEY 27 A1 15 18 A2 DO NOT ALTER VT300 400 300D 400D Electrics enclosure Motor 1 Fan 1 Solenoid 1 Fan 2 Solenoid 2 Motor 2 Supply 1 5 To electrics enclosure 1 Su...

Page 30: ...Solenoid 10 Compressor 11 Cooling fan 12 Power in 12 11 8 7 6 5 4 3 9 2 1 10 1 Thermal fan switch 2 Pressure switch 3 Exhaust fan 4 Thermal trip 5 6 7 8 Connection blocks 9 Solenoid 10 Compressor 11 C...

Page 31: ...fans 4 Thermal trip 5 6 7 8 Connection blocks 9 Solenoid 10 Motor 11 Aftercooler fan 12 Thermal fan switch 13 Timer box Note Timer box only used on Dryer models NOTE The cooling fans remain live even...

Page 32: ...E EARTH BROWN BLACK Solenoid 1 Solenoid 2 Fan 1 Fan 2 Overload set to 10 amps DO NOT ALTER NOTE Fans only used on dryer models L1 L2 L3 SUPPLY VT300 400 300D 400D PRESSURE SWITCH MOTOR L1 L2 L3 SUPPLY...