46
Eliminator Vacuum Tank (Tandem) User Manual
2 . Pull the Blue wire out enough to make a small loop .
3 . Cut the Orange wire and the Blue wire (Figure 63) .
4 . Push the Blue wire leading to the 16-pin plug back into the wire loom (this wire is not needed) .
5 . Strip about 3/8” to 1/2” of both cut Orange wire ends and the remaining Blue wire end .
6 . Assemble the wires as shown in Figure 64 . Use a heat shrink solder connector with a heat gun (this will solder the wires
together and shrink seal the ends) or twist the exposed wires together and solder with a soldering iron .
DO NOT
use
crimp connectors for this connection as they can work themselves loose and create an intermittent connection .
7 . If using a soldering iron, after the solder has cooled, use electrical tape to wrap the wires from about 1” above the joint
to about 1” below the joint .
8 . Push the soldered and sealed joint back into the wire loom leaving only the Orange wire tail exposed .
Rite Rate Wiring Installation
Figure 65 shows the Rite Rate system wiring installation and connections .
1 . Connect the 16-pin plug on the Console Cable to the 16-pin receptacle on the back of the Raven SCS660 Controller .
2 . Connect the 3-pin plug on the Sky Trak GPS to the 3-pin receptacle on the back of the Raven SCS660 Controller .
3 . Connect the Orange wire of the Console Cable to the Blue wire of the Sky Trak GPS .
4 . Place the Sky Trak GPS as high as possible on the tractor in a space that will allow the Sky Trak GPS unrestricted
exposure to the sky . The Sky Trak GPS has a magnetic base for placement on a metal surface for mounting .
5 . Connect both connectors of the Console Cable to the Flow Control Cable .
6 . Connect a White wire of the Flow Control Cable to the White wire of the Raven 660 Boost Box .
7 . Connect the Yellow/Green wire connector of the Flow Control Cable to the Yellow/Green wire connector of the Raven
660 Boost Box .
8 . Connect the Black wire of the Flow Control Cable to the Red wire of the Raven 660 Boost Box .
9 . Connect the wires from the Raven 660 Boost Box to the Down Pressure Block .
10 . Connect the Blue wire of the Flow Control Cable to the Red wire of the Power Cable to the Flow Meter .
11 . Connect a White wire of the Flow Control Cable to the Black wire of the Power Cable to the Flow Meter .
12 . Connect the 3-pin connector of the Flow Control Cable to the 3-pin connector of the Extension Cable .
13 . The remaining White wire and the Brown wire of the Flow Control Cable are not used . Wrap the ends with electrical
tape to protect the connectors .
14 . Connect the 4-pin connector of the Power Cable to the 4-pin connector of the Krohne Flow Meter .
15 . Connect the 3-pin connector of the Extension Cable to the 3-pin connector of the Krohne Flow Meter .
16 . Return to the Console Cable and connect the White wire from the smaller wire loom to the Tractor Ground .
17 . Connect the Red wire from the smaller wire loom to a Key Sw12 VDC power source .
Rite Rate Console Cable Preparation (Continued)
Figure 64
Heat Shrink Solder
Connector
TROUBLESHOOTING
Summary of Contents for ELIMINATOR VACUUM TANK Series
Page 2: ...Serial Number Date of Purchase Purchased From Dealer s Address Dealer s Telephone...
Page 4: ......
Page 8: ...4 Eliminator Vacuum Tank Tandem User Manual...
Page 9: ...Eliminator Vacuum Tank Tandem User Manual 5 Safety...
Page 15: ...Eliminator Vacuum Tank Tandem User Manual 11 Technical Data...
Page 19: ...Eliminator Vacuum Tank Tandem User Manual 15 Operation...
Page 31: ...Eliminator Vacuum Tank Tandem User Manual 27 Maintenance...
Page 45: ...Eliminator Vacuum Tank Tandem User Manual 41 Troubleshooting...
Page 52: ...48 Eliminator Vacuum Tank Tandem User Manual...
Page 53: ...Eliminator Vacuum Tank Tandem User Manual 49 Notes...
Page 54: ...50 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Page 55: ...51 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Page 56: ...52 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Page 57: ......