6 / 24
0006081445_201011
E
N
G
L
I
S
H
TECHNICAL SPECIFICATIONS
TBG 45 PV
TBG 60 PV
THERMAL CAPACITY
MAX kW
450
600
MIN kW
100
120
OPERATION
Progressive two stage
NOx EMISSIONS
mg/kWh
< 80 (Class III according to EN 676)
MOTOR
kW
0,50
0,75
r.p.m.
2730
2800
ABSORBED ELECTRICAL POWER*
kW
0,71
0,98
line FUSE
230 V
4 A
4 A
IGNITION TRANSFORMER
26 kV - 40 mA - 230/240 V - 50/60 Hz
VOLTAGE
1N ~ 230 V + 10% - 15% - 50/60 Hz
PROTECTION RATING
IP 44
FLAME DETECTOR
IONIZATION PROBE
NOISE**
dBA
73
75
AMBIENT TEMPERATURE OF OPERATION
MAX
° C
40
MIN
° C
- 10
WEIGHT
kg
42
44
Natural Gas (G 20)
FLOW RATE
MAX
m³n/h
45,3
60,3
MIN
m³n/h
10,1
12,1
PRESSURE
MAX
mbar
360
STANDARD ACCESSORIES
TBG 45 PV
TBG 60 PV
BURNER COUPLING FLANGE
2
2
INSULATING GASKET
1
1
STUD BOLTS
N° 4 M 12
N° 4 M 12
HEXAGONAL NUTS
N° 4 M 12
N° 4 M 12
FLAT WASHERS
N° 4 Ø 12
N° 4 Ø 12
*) Total absorption at start with ignition transformer on and fan motor supplied at 50 Hz.
**) Noise levels measured in the laboratory of the manufacturer with burner running on test boiler, at maximum nominal thermal output.
TECHNICAL AND FUNCTIONAL SPECIFICATIONS
• Gas burner with low NOx and CO emissions in accordance
with "Class III" of the European standard EN676
• Two-stage progressive output operation.
• Adjustment of the number of revolutions of the fan according
to the operating stage through a frequency converter to obtain
a noticible reduction in noise and electricity consumption.
• Combustion head with exhaust gas recirculation which allows
extremely low polluting emissions with particular attention to
nitric oxide (NOx).
• Maintenance facilitated by the fact that the mixing unit can be
removed without having to remove the burner from the boiler.
• Combustion air flow adjustment with closure of the shutter when
paused to prevent any heat dispersion to the flue.
• Gas adjustment through the single stage working valve control
-
led electromagnetically.
• Possibility to integrate the burner with a kit for valve seal control.
• Equipped with 4 and 7 pole connectors, 1 flange and 1 insulating
seal for fixing to the boiler.
• Gas train exit from below.