![baltur GI MIST 1000 DSPNM-D Instructions For Use Manual Download Page 15](http://html.mh-extra.com/html/baltur/gi-mist-1000-dspnm-d/gi-mist-1000-dspnm-d_instructions-for-use-manual_470396015.webp)
E
N
G
L
I
S
H
14 / 34
0006080766
WIRING DIAGRAM FOR DANDOSS PUMP MODEL KSVB 1000 ÷ 6000 R
N° 0
00
29
00
43
0
Return
Delivery
Cock
Cock
Pressure gauge
Intake
Pressure regulator screw
DIAGRAM OF A DISMANTLED (CB) CHARLES BERGONZO NOZZLE (WITHOUT PIN)
N°
B
T
93
53
/1
Nozzle ID:
Flow rate in kg/h
Spray angle (30° - 45° - 60° - 80°)
Flow ratio (1/3 =B3 - 1/5 = B5)
Viton O-ring
(oil and temperature reristant)
Air turbulence chamber
Fuel outlet
Fuel return holes
Fuel inlet
Fuel return
N.B. For the nozzle to operate properly, its “return” section must never be completely closed.
This is achievedby regulating when the burner is started up for the first time. In practice, when the nozzle is operating at the maximum flow
rate, the difference in pressure between the “delivery” (pump pressure) and “return” (pressure at hte returnpressure regulator) pressures
(running to and from the nozzle) must be at least 2÷3 bar.
Example:
Pump pressure
20 bar
Pump pressure
22 bar
Return pressure
20 - 2 = 18
Return pressure 22 - 3 = 19 bar
20 - 3 = 17
22 - 2 = 20 bar