Make sure that the sealing ring 6 is placed (at the place of connection of the ventilator plug) before
installing the separator onto the boiler (see Scheme 9);
4)
Install the channel separator 2 onto the boiler, controlling that the plug won’t “bite on” the sealing ring 6
(see Scheme 9);
5)
Fix the channel separator by four screws 3 (previously install first the plain washer4, and then the ring 5 on
each screw) (see Scheme 9);
6)
Make sure that there are sealing rings 7 (2 pcs.) placed on the inlet and outlet of the channel separator before
further installation of the smoke exhauster and air duct pipes (see Scheme 9);
7)
The installation of the air inlet pipe and the smoke exhauster pipe must be effectuated in accordance with
Scheme 6 (see p.9.2.1, page16).
1-
Boiler;
4- plain washer 5,3х10 DIN 125; 6- sealing ring
2-
Channel separator 5- ring 005-008-19-2-2 GOST 9833-73; 7- sealing ring
3-
Screw Ph - 4,8х60 DIN 7981;
Scheme 9. Channel separator installation scheme