Package contents:

- Ceiling plate with cover, Telescopic rods with luminaire heads
- OyO D 2: 2 x optics 100° / OyO D 3: 3 x optics 100°
- Mounting material and Insulation tubes.

Optic 100°, Article no. 6000-63
(OyO D 2: 2 piece included in delivery,
 OyO D 3: 3 piece included in delivery)

Optic 60°, Article no. 6000-62
(Not included in the scope of delivery)

Optic 20°, Article no. 6000-61
(Not included in the scope of delivery)

EN

4 / 5

Operating instructions

When adjusting the height or swivelling out the lamp, always 
hold the telescopic rod firmly.

The  100°  optic  holds  magnetically  to  the  luminaire  head.           
With the 100° optic, wide beam lighting is achieved with better 
glare control. It is particularly suitable for applications in which 
wide and preferably glare-free illumination is desired.

Luminaire head without optics: The luminaire head has a small 
anti-glare cone. Even without additional optics, good glare 

 

 

 

control is achieved with the widest possible beam angle of 120°.

Other optics can be ordered separately:
Optic 60°: The 60° optic allows for a wider but still slightly ac-
centuated horizontal or vertical illumination of larger objects, 
walls or tables.

Optic 20°: The 20° optic is suitable for applications in which 
accent light is desired for targeted and punctual illumination       
(e.g. for images or objects).

2

3

4

1

620 mm

620 mm

The ball joint in the ceiling flange has been tested and adjusted 
at the factory.

Adjust the ball joint belatedly:

Disconnect the power supply during adjustment    

(remove fuse).
Loosen the cover from the mounting plate − held in place mag-
netically (see also page 3 / section 5). Release the rods from the 
ball joint if necessary (loosen the set screw in the ball joint). The 
universal joint can be adjusted with two screws in the cylinder 
(see sketch).

Then reassemble the cover and rods (according to the mounting 
instructions on page 3 / section 5 to 8). 

When the luminaire is completely mounted, the power 
supply may be switched on again 

(switch on the fuse).

5

The magnetic contacts must lie cleanly during operation so that 
contact and consequently correct current conduction can be 
ensured.

Correct

Incorrect

Switching ON / OFF and dimming via button on luminaire head:
Switching: Press the button shortly.
Dimming:  Keep the button pressed (step dimming).

Important note: The luminaire must not be operated 
with an external dimmer.

M 1203/32637/SaWa/20.05.2021

5

Magnet must be 
attached to the rod.

3

3

Telescopic rod

Luminaire head

1

Ceiling flange

Button

2

Do 

NOT 

adjust this screw

(with the cable lug)!

Loosen or tighten 
these 2 screws 
accordingly.

Mounting plate

Cylinder bronze 
washer 

Telescopic rod

620 mm

100°

20°

60°

4

Luminaire head

Optic

5

Ball joint