Bally Modularm 75 Installation & Operating Instructions Manual Download Page 3

MODULARM CORPORATION
61 MALL DRIVE, COMMACK, NY   11725

TEL 631-864-3860 ∙ FAX 631-864-3863

TABLE OF CONTENTS

MODEL 75 & 75B GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . .. . . . . .. . . . . 1

CONTROLS, INDICATORS & FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

INSTALLING THE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

SETTING UP THE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . 3

OPERATING SEQUENCE OF ALARM  . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . 4

CALIBRATION  . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . .   . . . . . . . . . . . . . . . . . .  4

MODEL 75C CONTROL INSTRUCTIONS . . . . . . . . . .. . . . .  . . . . . . . . . . . . . . .  5
 
SPECIAL OPTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . . . . . . . . . . . . . .  6

SAMPLE SPECIFICATION MODEL 75 & 75B  . . . . . . .. . . . . .  . . . . . . . . . . . . . . 6

WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . . . . .. . . . . . . . . . .  . .7

MODEL 75 & 75B GENERAL DESCRIPTION

The   Modularm   Model   75   Temperature   Monitoring   System   is   designed   to   constantly 
monitor temperature and will provide audible, visual and remote notification whenever 
refrigeration failure occurs.  The basic operation of the Model 75 is described as follows:

Through the use of an electronic temperature probe the ambient temperature of a walk-
in cooler or freezer or other temperature sensitive environment is constantly monitored. 
When the monitored temperature goes above or below the temperature setpoints an 
electronic time delay circuit is activated.  The purpose of the time delay is to override 
defrost cycles and other short term changes in temperature that occur during normal 
operation.  When temperature in the monitored area exceeds the setpoints beyond the 
length   of   the   time   delay   the   alarm   activates,   providing   audible,   visual   and,   if   so 
connected, remote notification that an alarm condition has occurred.

(Note 1):  The Model 75 offers Battery Backup as an option.  (75B)  When so ordered, 
the Model 75B will also annunciate any power failures which may occur.

(Note 2):   The Model 75 offers Thermostatic Control as an option. (75C)   When so 
ordered, the Model 75C will provide electronic temperature control.

-1-

Summary of Contents for Modularm 75

Page 1: ...REV 3 2013 IM 419 13 INSTRUCTION MANUAL Modularm 75 Install Operation IM 419 13 Installation Operating Instructions for Modularm 75...

Page 2: ...DISPLAY RESET SWITCH A TO LEFT TO STOP DISPLAY FROM BLINKING 2 SELECT FAHRENHEIT OR CENTIGRADE WITH DISPLAY MODE SWITCH B 3 SELECT AND ADJUST HIGH AND LOW SETPOINTS WITH SETPOINT DISPLAY SWITCH E AND...

Page 3: ...probe the ambient temperature of a walk in cooler or freezer or other temperature sensitive environment is constantly monitored When the monitored temperature goes above or below the temperature setpo...

Page 4: ...on Digital Readout Holding up displays High Setpoint Holding down displays Low setpoint F TIME DELAY SELECT SWITCH Provides selection of length of Time Delay before alarm activates G H STATUS LIGHTS...

Page 5: ...220VAC Optional if so ordered through suitable conduit to the hole in the top of the enclosure Connect to the black white 18 wires which are located in the small compartment above the actual alarm un...

Page 6: ...AS FOLLOWS GREEN LIGHT SAFE CONDITION BLINKING RED LIGHT ABNORMAL CONDITION TIME DELAY INITIATED SOLID RED LIGHT ALARM CONDITION HORN SOUNDS RELAY ACTIVATED 6 VOLT ONE SECOND PULSE GENERATED ACROSS PU...

Page 7: ...share setpoints for the alarm and control function the pin jumper matrix and separate control setpoints are deleted This matrix is the two rows of gold pins located near the Control Terminal Strip an...

Page 8: ...r the monitoring of large rooms or smaller temperature sensitive rooms Alarm scans and displays probe temperatures at four second intervals Otherwise operation is identical to a standard alarm SAMPLE...

Page 9: ...MODULARM CORPORATION 61 MALL DRIVE COMMACK NY 11725 TEL 631 864 3860 FAX 631 864 3863 WIRING DIAGRAM TYPICAL REMOTE NOTIFICATION APPLICATIONS 7...

Page 10: ...AND CONNECTION POINTS A FIVE SCREW TERMINAL STRIP IS SHOWN AS CONNECTION POINTS FOR REMOTE NOTIFICATION FUNCTIONS ALSO ON PAGE 7 BACK PAGE OF INSTRUCTION BOOKLET WIRING DIAGRAMS OF SOME TYPICAL REMOT...

Page 11: ...5 WIRE WIRE MAY BE LENGTHENED IN EXCESS OF 1000 OR SHORTRENED WITHOUT AFFECTING ACCURACY OPERATING 120VAC 1 45mA OTHER RANGES AVAILABLE WARRANTY All systems and components manufactured by Modularm Cor...

Reviews: