background image

REV: 5/2013  

IM-268S-11  2013 © Bally Refrigerated Boxes, Inc.

    

 

 

7

 

REACH-IN DOORS 

 

Replacing magnetic gasket on Reach-In doors 

 

A. To replace the magnetic door gasket, it may be necessary to remove the door 

from the Walk-In. Simply open the door and lift it off the hinge bases. Lay the 
door facedown on a flat working surface.  

B. Remove the defective gasket and clean the surface where the new gasket will be 

placed.  

C. Position the new gasket and tap firmly into place with a wood block and 

hammer. Be sure the gasket lies flat.  

See Figure 2.

 

D. Place the door back on the hinges. Check the door for proper operation and seal. 

Part Numbers: 

#016582 – 18½” x 30” 
#016584 – 20” x 30” 
#016583 – 30” x 30” 

 

 
Adjusting self-closing hinges on Reach-In doors 

 

A. Do not oil door hinges. If dirt accumulates on the Delrin cams and causes them to bind, apply dry silicone 

spray lubricant.  

B. Begin by determining whether the hinge is correctly adjusted. When the strap of the hinge is flush with the 

flange, there must be clearance as shown in 

Figure 9. 

Without clearance, the door may not close. Adjust 

the hinge by following these steps:  
1. Open the door 90 degrees and lift the door from its hinge bases.  
2. Adjust the hinges as shown in 

Figure 10

 

a. Put a pencil mark on cam and on hinge; this enables you to see how much the cam is being 

turned. 

b. Loosen bottom nut and turn half way off. 
c. Tap against bottom of nut with a hammer until pin and cam are loose.  The reason for this is the 

pin has a tapered shaft. 

d. Turn cam in direction of the arrow in increase clearance; opposite direction to decrease. 
e. Hold cam in position and tighten bottom nut securely. 

3. Replace the door on its hinge bases. Check to make sure door operates properly. 

 

 

 

 

 

Figure 9 

Figure10 

Summary of Contents for IM-268S-11

Page 1: ...nels 5 Shimming Walk In door hinges 5 Anti Condensate Heaters Replacing anti condensate heater element around door frame of hinged Walk In doors 6 Reach In Doors Replacing magnetic gasket on hinged Reach In doors 7 Adjusting self closing hinges on Reach In doors 7 Replacing hinges on Reach In door panels 8 Replacing anti condensate heater element around frame of hinged Reach In doors 8 Pressure Re...

Page 2: ...ge or heater failure Contact a serviceman immediately E Keep door gaskets clean with a solution of water and mild soap F Inspect refrigeration units frequently for proper function of evaporator condenser fan motors drain pan heaters defrost controls and drain line heaters Condensate water must never be permitted to drip on the Walk In floor Drain pan or drain line heater failure will result in ice...

Page 3: ...84 016546 34 x 78 016547 34 x 84 054117 36 x 78 054119 36 x 84 032999 42 x 78 032999 42 x 84 016548 48 x 84 016549 60 x 84 A Open the door 90 degrees B Grasp the old gasket and pull it away from the interior skin of the door Clean the surface where the new gasket is to be placed C Position the new gasket tap it into place with a wood block and hammer Do not force the gasket into place excessive fo...

Page 4: ...away D Secure the new D 1000 latch base to the Walk In door with three 20 oval head machine screws E Insert the new strike bolt with attached strike plate into the holes on the door jamb panel F Screw the new inside knob onto the strike bolt until adequate tension is applied to the rod to hold the assembly firmly in place Tighten the set screw on the side of the knob using a 5 32 allen key to allo...

Page 5: ...d properly no shimming is required Shim only where misapplication or poor installation of the door panel have caused the door cap to seal improperly If the door cap toes outward at the top or bottom of the latch side of the panel shim the diagonally opposite hinge base outward forcing the corner of the door cap back into alignment with the door frame for a positive seal See Figure 6 B To shim hing...

Page 6: ...ed with an installation diagram F Apply a small bead of silicone caulking around the perimeter of the door frame to retain the new heater element until the door strikes can be reinstalled G Guide the leads of the new heater element into the switch box containing the light switch Note Only heater wire leads are to protrude into the switch box this will prevent premature heater burnout Press the hea...

Page 7: ...accumulates on the Delrin cams and causes them to bind apply dry silicone spray lubricant B Begin by determining whether the hinge is correctly adjusted When the strap of the hinge is flush with the flange there must be clearance as shown in Figure 9 Without clearance the door may not close Adjust the hinge by following these steps 1 Open the door 90 degrees and lift the door from its hinge bases ...

Page 8: ...he door frame Remove the strikes See Figure 12 C Remove the cover plate from the junction box on the inside of the door frame Locate and disconnect the defective heater element from the door frame D Remove the defective heater element from the door frame E Apply a small bead of silicone sealant around the perimeter of the door frame to retain the new heater element Press the new heater element fir...

Page 9: ...steel door strikes by removing the two screws in the top and bottom flanges C Disconnect the defective anti condensate heater in the junction box at the top of the door Discard the old heater D Insert the new heater 015628 and reassemble the door strikes Exercise care not to pinch the heater wire beneath the door strikes E Replace the port door and refasten the screws F Reconnect the electrical po...

Page 10: ...e door frame C Install new closer and J hook onto door and frame using the existing holes If for any reason the existing holes do not line up with the holes in the new closer you will be required to drill and tap the door at the location of the holes for the new closer mounting base Once firmly secured rotate the cover back down over the base and snap into place D Adjust the J hook if required to ...

Reviews: