Balluff STM V10-BP-00 Manual Download Page 2

Max. frequency response

V10B: 

500Hz

V10F

: 3kHz

V10G

: 500Hz

    Functional principle

pulsed

Power supply indicator

LED green (PWR)

Function indicator

LED yellow (OUT)

Alarm  indicator

LED green (PWR) blinking

Alarm output

200mA, 50ms pulse length

Operating voltage

10 ... 30VDC (max.)

Output current

200mA

Current consumption

V10B:

 45mA / 180mA

(Ø / peak)

V10F:

 45mA / 90mA

V10G

:45mA/180mA

Weight

65g

Casing material

ABS

Operating  temperature

-10°C bis +55°C

Protection class

IP65

     Wiring

           8020132

VDC

brown

alarm

white

output

black

teach-in
pink/grey

GND

Z

L

Z

L

blue

NPN

VDC
brown

teach-in

pink/grey

alarm

white

output

black

GND

Z

L

Z

L

blue

PNP

V10-BP / V10-FP / V10-GP

Attention!

Connect amplifier to 10-30  VDC only!

Do not mount amplifier cable parallel to a

power line!

If the green LED is blinking (alarm

indicator) when the amplifier is in

operation (RUN), it indicates an unstable

signal. In this case, check whether the

sensor is dirty or out of alignment.

Caution!

Sensor and amplifier are only intended

 for object detection. Do not use amplifier

and sensor for personnel safety

applications!

05/2010

V10 menu navigation

RUN

slide-switch

    JOG-Switch

JOG-Switch

JOG-Switch

selection of

    selection with +/-

selection  with  +/-

      selection with +/-

main  menu

    confirm with

confirm  with

      confirm with

The actual setting is permanently lit up.

Flashing display means: indicated value can be selected. Confirm by pushing JOG-switch.

Operation

  The different operation modes and parameters are set by a 4-position slide-switch

  and a JOG-switch with push-button functionality.

- light-on/dark-on select;
- pulse stretching

- signal strength display;
- selected parameters:
(  +  =  tHi  ,  -  =  tLo )
- external TEACH

       inscription   function

JOG-switch

push-button
(confirmation of selection)

increment

decrement

slide-switch

OUT

OPT

TEA

RUN

- operation modes

- teach-modes

+

-

Dismount

Mount

Put device onto DIN rail clip as shown.
Then, connect sensor cable.

First unplug sensor cable connector.
Then take amplifier off the DIN rail clip as shown.

5

3

Connection

In- /Output

Sensor

3

1 (brown)     + VDC
2 (white)       remote teach
3 (blue)

    - GND

4 (black)        signal output

1

4

Standard:  - 0
M8, 3pole

1 + emitter
4 GND/shielding
3 + receiver

1 (brown)     + VDC
2 (white)

     alarm output

3 (blue)

    - GND

4 (black)

    signal output

5 (grey)

     remote teach

option -01:
M12, 5pole

1 (brown)     + VDC
2 (white)      alarm output
3 (blue)

    - GND

4 (black)        signal output

brown

+ VDC

white

alarm output

blue

- GND

black

signal output

pink

remote teach

Standard  -00:
PVC-cable, 5pole, 2m

option -02:
M8, 4pole

option -03:
M8, 4pole

4

1

3

2

1

2

4

slide-switch

JOG-switch

Output-

Mode

Option

0...250

0...250

  dark-on

  light-on

Parameter
lock

Turn
display

Display
o f f

Hysteresis

Default

  Hysteresis in %
  4 values (default 12)

  factory setting

3; 6; 9; 12

Y  E  S

n  o

Teach

fully automatic teach

1-point teach

2-point teach

Fine

tuning

  Potentiometer

Threshold low

Threshold high

 Alarm level

  Back to level 1

Operation

+ RemoteTeach

0....999

  Actual threshold high

  Actual threshold low

(see  teach-menu)

0...127

0...999

0...999

0...999

0...999

0...999

Signal
strength

+

-

Dark-On/
Light-On

 ms

 ms

level  0

    level 1

level 2

level 3

TEA

OPT

OUT

Y  E  S

n  o

Y  E  S

n  o

0...999

A  b  S

Push

Off Delay

On Delay

rEt

:  return to level 1

 Remote teach procedure

  The switching threshold of the amplifier can be
  adjusted remotely through the PLC via the
  teach-input (pink/grey).

  (N.B.: only in RUN mode!).

The remote teach procedure is
actuated by two pulses from the
PLC to the amplifier. The duration
of the first pulse selects the teach
mode (automatic or 2-point).

The duration of the second pulse
defines the storage of the
determined threshold value.

1.)   X = 2,0 - 4,5s:

Permanent storage (100.000 times max.); The successfull teach procedure is
confirmed by a signal of 100ms duration on the alarm output.

2.)   X = 0,1 - 1,5s:

Non permanent storage (until next power cutoff); The successful teach
procedure is confirmed by a signal of 100ms duration on the alarm output.

Required voltages

PNP

NPN

Input voltage          Signal „1“:

>9V

<3V

Input voltage          Signal „0“:

<5V

>6V

Input current:

<3mA

<3mA

b) Remote 2-point teach:

a) Fully automatic remote teach:

    2,0 - 4,5 s

alarm pulse

1

0

signal from PLC

 0,1 - 30 s

( teach duration)

X

(running process; preferably

several switching cycles)

teach point (condition1)

signal from PLC

X

0,1 - 30  s

    0,1 - 1,5  s

alarm pulse

0

1

teach point (condition2)

0,1 s

V10-BN / V10-FN / V10-GN

( -00 / -01 / -02 / -03)

All automatic teach procedures:
min. value of calculated threshold = 100
max. value of calculated threshold = 850

The nominal switching
threshold is calculated as
mean value of the detected
high und low signal level.
ALH, tHi und tLo are
determined referring to it
dependent on selected
hysteresis.

Especially recommended for cyclic
processes.

Nominal switching threshold,
ALH, tHi, and tLo are
adjusted automatically refer-
ring to the signal level in a
(fixed) relation to each other.

Higher signal level should be teached
first.

The nominal switching
threshold is calculated as
mean value between Pt1 and
Pt2.
ALH, tHi und tLo are
determined referring to it
dependent on hysteresis.

POt

: Adjustment of signal

        amplification in 127
        potentiometer steps.

AbS

:The nominal switching

        threshold may be moved
        manually.
        tLo, tHi, ALH remain
        in the before auto-
        matically adjusted
        relation to each other.

tLo

: threshold low

tHi

:  threshold high

ALH

:alarm level

hyst.

AbS

hyst.

hyst.

hyst.

hyst.

hyst.

hyst.

2 x hyst.

hyst.
hyst.

hyst.

hyst.

hyst.

nom.  threshh.

nom.  threshh.

nom.  threshh.

Pt1

Pt2

tHi

ALH

tLo

ALH

ALH

ALH

tHi

tHi

tHi

tLo

tLo

tLo

signal

signal

tHi

tLo

ALH

alarm

output

Pushing the JOG-switch activates the teach procedure. Display   rdy   confirms successful
execution of the teach procedure.
- Repeat teach procedure after every change in hysteresis setting.
- Hysteresis recommendation: For distances > 50% of nominal => use values 9 or 12.

  Push JOG-switch to start teach
procedure. Switching threshold
is adjusted by repeated inserting
and removing of the object in the
sensing beam.

  Pushing of the JOG-switch
terminates the procedure.

The object is placed statically in
the sensing beam.

  Single push on the JOG-switch
executes the teach procedure.

Positioning of object 1 (resp.
distance 1) in the sensing beam
=>  Push JOG-switch;

Positioning of object 2 (resp.
distance 2) in the sensing beam
=>  Push JOG-switch

Manual fine tuning of all relevant
parameters:

- for optimisation after automatic
  teach or
- as fully manual adjustment
  without automatic teach.

(Only recommended for
processes which cannot be
adjusted by one of the automatic
procedures or for correction of
an automatic teach )

 teach menu and teach instruction

Manipulation

 Action

 Notice

info@balluffstm.de     www.balluffstm.com