39
BVS Cockpit
IO-Link station diagnostics
Bit
Meaning
0...3
-
4
Supply voltage short circuit (pin 3) (IO-Link mode)
5
Overload warning pin 2 or pin 4
6
Actuator warning pin 2 or pin 4
7
Supply voltage short circuit (pin 3) (IO mode)
IO-Link extended diagnostics
Bit
Meaning
0
IO-Link device connected
1
-
2
-
3
Supply voltage short circuit (pin 3)
4
Overload warning pin 4
5
Overload warning pin 2
6
Actuator warning pin 4
7
Actuator warning pin 2
Modules for use as digital I/O port
All of these modules feature the same design:
•
Input pin 4
•
Output pin 4
•
Restart pin 4
•
Input pin 2
•
Output pin 2
•
Restart pin 2
Only one bit is used in each case
Bit
Meaning
0
Input, output or restart information
1...7
-
5
Overload warning pin 2 or pin 4
6
Actuator warning pin 2 or pin 4
7
Supply voltage short circuit (pin 3) (IO mode)
5.7.5
Parameter configuration
Device Parameter
Slot0, Subslot 1
Index
Byte
Bit
Length
Contents
Values
Default
1
0
0
1 bit
IO-Link diagnosis
0/1
0
2
1
0
1 byte
IO-Link port function pin 4
0/1/3/4/5/6
0
2
0
1 byte
IO-Link port function pin 2
0/1/2/3
0
3
3
0
1 byte
IO-Link safe state pin 4
0/1/2
0
4
0
1 byte
IO-Link safe state pin 2
0/1/2
0