BVS ID-M1280xF1-xx-xxx
108
english
4.4.6 Events
Event Code
Event Type
Event – Description – Remedy
Device Status
0x1850 (6224)
Notification
Process Data profile selection non
applicable – Default value is used.
0 – Device is operating properly.
0x1851 (6225)
Notification
Process Data Update Timeout – for
information purposes only
0 – Device is operating properly.
0x1852 (6226)
Warning
Several Process Data Update Timeout
– for information purposes only.
0 – Device is operating properly.
0x4000 (16384)
Error
Temperature Fault – Overload – The
BVS ID is operated outside of the
device-specific temperature limits.
Risk of device damage
4 – Failure
0x4210 (16912)
Warning
Device Temperature Overrun – Clear
Heat Of Source – Risk of device
damage. The BVS ID is too hot.
→
Remove heat source, provide the
BVS ID with heat insulation if
necessary.
2 – Out-of-Specification
0x4220 (16928)
Warning
Device Temperature Underrun –
Insulate Device – Risk of BVS ID
damage. The BVS ID is too cold.
→
Insulate the device.
2 – Out-of-Specification
0x5110 (20752)
Warning
Primary supply voltage exceeded
→
Check for deviations in the supply.
2 – Out-of-Specification
0x5111 (20753)
Warning
Primary supply voltage below
minimum value
→
Check for deviations in the supply.
2 – Out-of-Specification
0x8CD0 (36048)
Warning
Inclination alarm
→
Check installation
1 – Maintenance-Required
0x8CD1 (36049)
Warning
Vibration alarm
→
Check machine.
0 – Device is operating properly.
0x8CFF (36095)
Warning
Low signal quality level
0 – Device is operating properly.
0x8D00 (36096)
Warning
The measured value is below the
measurement range. Accuracy cannot
be warranted.
2 – Out-of-Specification
0x8D01 (36097)
Warning
The measured value is above the
measurement range. Accuracy cannot
be warranted.
2 – Out-of-Specification
0x8D02 (36098)
Warning
The measured value is below the
detection zone, a measured value can
not be determined.
→
check application.
2 – Out-of-Specification
0x8D03 (36099)
Warning
The measured value is above the
detection zone, a measured value
cannot be determined.
→
check application.
2 – Out-of-Specification
0x8D04 (36100)
Warning
A measured value can not be
determined.
→
check application.
2 – Out-of-Specification
0x8D05 (36101)
Warning
Measurement errors/redundancy
check failed.
→
check application.
2 – Out-of-Specification
0x8D07 (36103)
Warning
The calculation of the basic statistics
was stopped automatically to avoid a
buffer overflow.
0 – Device is operating properly.
0x8D0B (36107)
Warning
Overload or short circuit at pin 2
→
check wiring.
2 – Out-of-Specification
0x8D0D (36109)
Warning
Wrong load/cable break, analog
power output pin 2
→
check cabling or connected
devices.
2 – Out-of-Specification
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...