www.balluff.com
27
10
LED and Beeper Indications
BVS HS-PC
Industrial Corded Handheld Barcode Reader
10
LED and Beeper Indications
The reader’s beeper sounds and its LED illuminates to indicate various
functions or errors on the reader. An optional “Green Spot” also per-
forms useful functions. The following tables list these indications. One
exception to the behaviors listed in the tables is that the reader’s func-
tions are programmable, and so may or may not be turned on. For
example, certain indications such as the power-up beep can be dis-
abled using programming barcode labels.
Indicator
Description
LED
Beeper
Power-up
Beep
The reader is in
the process of
powering-up.
N/A
Reader beeps
four times at high-
est frequency and
volume upon
power-up.
Good Read
Beep
A label has been
successfully
scanned by the
reader.
LED behavior
for this indica-
tion is configu-
rable via the
feature “Good
Read: When to
Indicate”
(see the OPM
for information.)
The reader will
beep once at cur-
rent frequency,
volume, mono/bi-
tonal setting and
duration upon a
successful label
scan.
ROM Failure
There is an error
in the reader's
software/pro-
gramming
Flashes
Reader sounds
one error beep at
highest volume.
Limited
Scanning
Label Read
Indicates that a
host connection
is not estab-
lished.
N/A
Reader 'chirps'
six times at the
highest fre-
quency and cur-
rent volume.
Reader
Active
Mode
The reader is
active and ready
to scan.
The LED is lit
steadily
a
N/A
Reader
Disabled
The reader has
been disabled by
the host.
The LED blinks
continuously
N/A
Green Spot
a
flashes
momentarily
Upon successful
read of a label,
the software shall
turn the green
spot on for the
time specified by
the configured
value.
N/A
N/A
Image Cap-
ture
When ready to
capture image
Blue light
flashes 2 times
when updating
N/A
a
Except when in sleep mode or when a Good Read LED Duration other than
00 is selected