50
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
Wedge Quiet
Interval
Specifies amount of time to look for keyboard activity before reader breaks keyboard connection
in order to transmit data to host. The selectable range for this setting is 00 to 990 milliseconds
(00-0x63 by 01) in increments of ten milliseconds.
See
in “References” for detailed
information and examples for setting this feature.
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface. The selectable range
for this feature is from 0 to 99 seconds.
See
in “References” for detailed information and examples for setting this feature.
Set Wedge Quiet Interval
To configure this feature, scan the ENTER/
EXIT PROGRAMMING MODE barcode
above, then the barcode at left followed by
the digits from the Alphanumeric characters
in
representing your
desired character(s). End by reading the
ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You
can then start again at the beginning.
CANCEL
$CKBQI
~
DEFAULT
0A = Quiet Interval is
100 milliseconds
Set Intercode Delay
To configure this feature, scan the ENTER/
EXIT PROGRAMMING MODE barcode
above, then the barcode at left followed by
the digits from the Alphanumeric characters
in
representing your
desired character(s). End by reading the
ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You
can then start again at the beginning.
CANCEL
$CKBID
~
DEFAULT
00 = No Wedge Intercode Delay
Summary of Contents for BVS HS-P Series
Page 1: ...Balluff BVS HS P Family Industrial Handheld Barcode Readers Operation Manual english...
Page 16: ...16 1 Introduction Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 30: ...30 2 Setup Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 44: ...44 3 Configuration Using Barcodes Balluff BVS HS P Family Industrial Handheld Bar Code Readers...
Page 54: ...54 3 Configuration Using Barcodes Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 202: ...202 3 Configuration Using Barcodes Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 206: ...206 3 Configuration Using Barcodes Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 236: ...236 3 Configuration Using Barcodes Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 286: ...286 6 Appendix B Sample Barcodes Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 300: ...300 7 Appendix C Standard Defaults Balluff BVS HS P Family Industrial Handheld Barcode Readers...
Page 312: ...312 9 Appendix E Scancode Tables Balluff BVS HS P Family Industrial Handheld Barcode Readers...