4.4.4 Connector type S147
BTL7 standard
Pin
BTL7-S5_ _-…-S147
BTL7-S5_ _B-…-S147
1
–Data
2
+Data
3
+Clk
4
–Clk
5
10…30 V
6
GND
7
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-5: Connection assignment BTL7…-S147
Fig. 4-12: Pin assignment of S147 (view of connector pins of
transducer), 7-pin M16 circular plug
4.4.5 Cable connection
BTL7 standard
BTL7 USB
configurable
Cable
color
BTL7-S5_ _-…-KA
BTL7-S5_ _-…-FA
BTL7-S5_ _B-…-KA
BTL7-S5_ _B-…-FA
BTL7-S510-…-KA
BTL7-S510-…-FA
BTL7-S510B-…-KA
BTL7-S510B-…-FA
YE yellow
+Clk
+Clk
GY gray
+Data
+Data
PK pink
–Clk
–Clk
RD red
Not used
1)
La
2)
GN green
–Data
–Data
BU blue
GND
GND
BN brown 10…30 V
10…30 V
WH white
Not used
1)
Lb
2)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
2)
Communication line
Tab. 4-6: Connection assignment BTL7… cable
Clk, Data and supply are twisted in pairs (see
Fig. 4-13:
+Clk
–Clk
+Data
–Data
GND
+24 V
YE
PK
GY
GN
BU
BN
Evaluation
or
controller
Connection example for BTL7-S…-cable 24 V DC with
evaluation/controller
4.5
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
– Connect the transducer and controller using a shielded
cable.
Shielding: Copper filament braided, at least 85%
coverage
– Connector version: Shield is interally connected to
connector housing.
– Cable version: On the transducer side, the cable
shielding is connected to the housing.
Ground the cable shielding on the controller side
(connect with the protective earth conductor).
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer cylinder and strong, external
magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Cable length
BTL7-S…
Max. 500 m
1)
1)
Prerequisite: Construction, shielding and routing preclude the effect of any
external noise fields. Required cable cross-section ≥ 0.6 mm
2
or
≤ AWG19.
Tab. 4-7: Cable length BTL7
For notes on cable length, see Technical data
4
Installation and connection (continued)
BTL7…-
cable
BTL7-S5 _ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S140/S147/KA _ _ /FA _ _
Micropulse Transducer - Rod Style