10.1 Accuracy
The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-S-3112-4Z float.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Typical
±10 µm
Sampling rate
Dependent on nominal length
At nominal length = 500 mm
250 µs to 2 ms
500 µs
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
±50 µm
±0.01% FS
Temperature coefficient
1)
≤ 30 ppm/K
Velocity detectable max.
10 m/s
10.2 Ambient conditions
Ambient temperature
2)
–40 °C…+85 °C
Process temperature
3)
≤ 130 °C
Storage temperature
–40 °C…+100 °C
Relative humidity
< 90%,
non-condensing
Pressure rating (BTL rod)
≤ 300 bar
Pressure rating (float)
see Tab. 11-1
pH values
Process media
2…13.2
Cleaning media
1.6…13.2
(1.6…2 for ≤ 20 min)
Restrictions on process and
cleaning media
conditionally resistant to
chloride corrosion
Degree of protection per
IEC 60529
IP67
10.3 Dimensions, weights
Rod diameter
10.2 mm
Nominal length
≤ 2500 mm
Weight (depends on length)
Approx. 2 kg/m
Housing material
Stainless steel
Flange material
Stainless steel
Rod material
Stainless steel
Rod wall thickness
2 mm
Housing mounting
1 1/2" Tri-Clamp per
SSI 3A standard 74-06
and seal
BAM SE-XA-002-D38,
10.4 Supply voltage (external)
Voltage, stabilized
10…30 V DC
Residual ripple
≤ 0.5 V
pp
Current draw (at 24 V DC)
≤ 120 mA
Inrush current
≤ 500 mA
Reverse polarity protected
4)
to 36 V
Overvoltage protection
to 36 V
Dielectric strength (GND to
housing)
500 V AC
10.5 Output
BTL7-A… Output voltage
Load current
0…10 V and 10…0 V
≤ 5 mA
BTL7-C… Output current
Load resistance
0…20 mA/20…0 mA
≤ 500 Ω
BTL7-E… Output current
Load resistance
4…20 mA/20…4 mA
≤ 500 Ω
Short-circuit resistance
Signal cable to 36 V
Signal cable to GND
10.6 Input
Programming inputs La, Lb
10…30 V DC,
high-active
Overvoltage protection
to 36 V
1)
Nominal stroke = 500 mm, float in middle of measuring range
2)
Ambient temperature: maximum permissible temperature at the BTL
housing.
3)
Process temperature: maximum permissible temperature of the rod below
the flange (with media contact).
Certain production processes require e.g. sterilization at 120 °C…130 °C
for 0.5…1 hours (see Tab. 11-1).
4)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
10
Technical data
BTL7-A/C/E5 _ _ -M _ _ _ _ -SF-F _ _
Magnetostrictive Linear Position Sensor – Rod Style
Summary of Contents for BTL7-A5-M Series
Page 2: ...www balluff com...
Page 3: ...BTL7 A C E5_ _ M_ _ _ _ SF F_ _ Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 26: ......
Page 27: ...BTL7 A C E5_ _ M_ _ _ _ SF F_ _ User s Guide english...
Page 28: ...www balluff com...
Page 50: ......
Page 51: ...BTL7 A C E5_ _ M_ _ _ _ SF F_ _ Notice d utilisation fran ais...
Page 52: ...www balluff com...
Page 74: ......
Page 75: ...BTL7 A C E5_ _ M_ _ _ _ SF F_ _ Manuale d uso italiano...
Page 76: ...www balluff com...
Page 98: ......
Page 99: ...BTL7 A C E5_ _ M_ _ _ _ SF F_ _ Manual de instrucciones espa ol...
Page 100: ...www balluff com...
Page 122: ......
Page 123: ...BTL7 A C E5_ _ M_ _ _ _ SF F_ _ Instrukcja obs ugi polski...
Page 124: ...www balluff com...