4.5
Electrical connection
Fig. 4-6:
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
Retaining screws
Typical housing with connection terminal assembly, pin
assignment
Note the information on shielding and cable
routing (see Section 4.6).
Use 90°C rated conductors.
4
Installation and connection (continued)
4.4
Replacing electronics module
DANGER
Explosions
Opening the housing can result in sparks which can trigger
explosions in explosive atmospheres.
►
Do not open housing when an explosive atmosphere
may be present!
1.
Disconnect power source.
2.
Unscrew and remove housing cover.
3.
Note wire locations for re-assembly and disconnect
wiring.
4.
Disconnect the two electronics module retaining
5.
Carefully pull the electronics module out of the pressure
housing (avoid bending the measuring range).
6.
Carefully slide new electronics module into the pressure
housing (avoid bending the measuring range).
7.
Secure the electronics module using the two new
screws provided with the replacement module.
8.
Connect wiring (see Electrical connection on page
9.
Re-install the housing cover flush and tighten to
33…40 Nm (25…30 ft ∙ lb). Tighten secondary
retaining screws (ATEX).
BTL7-A/E501-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
Type of protection “db” and “ta”
Flameproof enclosure
Summary of Contents for BTL7-A/E501-M Series
Page 2: ...www balluff com...
Page 4: ...www balluff com...
Page 34: ......
Page 36: ...www balluff com...
Page 66: ......
Page 68: ...www balluff com...
Page 98: ......
Page 100: ...www balluff com...
Page 130: ......
Page 132: ...www balluff com...
Page 162: ......
Page 164: ...www balluff com...
Page 178: ...16 5 1 1 2 3 BTL 5 2 BTL BTL 5 BTL7 A E501 M_ _ _ _ J DEXC TA12 db ta...
Page 182: ...20 7 7 3 2 22 1 1 2 1 2 24 7 3 7 4 7 3 3 25 BTL BTL7 A E501 M_ _ _ _ J DEXC TA12 db ta...