8
Inverting
NOTICE!
Interference in function
Inverting while the system is running may result in
malfunctions.
►
Stop the system before inverting.
LED display Displayed values (example)
LED
At 0…10 V
At 4…20 mA
Initial situation:
– Transducer with magnet within measuring range
5.39 V
9.15 mA
1. Activate inverting
►
Activate
b
for at least 4 s.
> 4 s
b
5.39 V
9.15 mA
2. Invert gradient
►
Activate
a
and
b
simultaneously for at least 4 s.
> 4 s
a
b
After activation:
5.61 V
14.85 mA
⇒
The output gradient is inverted.
⇒
Current position value is displayed.
⇒
Inverting is deactivated.
3. Abort inverting
Inverting can be aborted without any changes
being saved after the
Activate inverting
step.
►
Briefly activate
a
and
b
simultaneously (< 1 s).
< 1 s
a
b
⇒
Current position value is displayed.
LED legend:
LED green
LED flashing green
LED red
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Summary of Contents for BTL6-A500-M PF-S115 Series
Page 1: ...BTL6 A C E G500 M _ _ _ _ PF S115 Betriebsanleitung deutsch...
Page 2: ...www balluff com...
Page 23: ...BTL6 A C E G500 M _ _ _ _ PF S115 User s Guide english...
Page 24: ...www balluff com...
Page 45: ...BTL6 A C E G500 M _ _ _ _ PF S115 Manual de instrucciones espa ol...
Page 46: ...www balluff com www balluff com...
Page 67: ...BTL6 A C E G500 M _ _ _ _ PF S115 Notice d utilisation fran ais...
Page 68: ...www balluff com...
Page 89: ...BTL6 A C E G500 M _ _ _ _ PF S115 Manuale d uso italiano...
Page 90: ...www balluff com...