background image

BTL5-A/C/E/G1_-M/U_ _ _ _-K-SR 32/K_ _
Trasduttori di posizione Micropulse – Versione a barra

8

italiano

Risol Isteresi
= Ripetibilità

Tensione

0,3 mV

Corrente

0,6 µA

minimo

5 µm

Campionamento:
Campo di misura

f

Standard

< 2000 mm

1 kHz

> 2000 mm

0,5 kHz

Deviazione linearità:
Campo
di misura < 500 mm

 > 500 mm

in µm

±100

 ±0,02 % FS

Coefficiente di temperatura
Uscita in tensione:
[150 µV/K + (5 ppm/K * P * U/NL)] * 

T

Uscita in corrente:
[0,6 µA/K + (10 ppm/K * P * I/NL)] * 

T

U = campo tensioni in uscita in [V]
I

= campo corrente in uscita in [mA]

NL= campo di misura nominale in [mm]

T= differenza di temperatura in [K]

P = posizione del datore di posizione

   in [mm]

Shock

100 g/6 ms

secondo IEC 68-2-27 

1

Shock continuo 100 g/2 ms
secondo IEC 68-2-29 

1

Vibrazioni    12 g, 10 sino a 2000 Hz
secondo IEC 68-2-6 

1

(rispettare /evitare le risonanze interne)
Resistente alla pressione fino a
600 bar in caso d'installazione in
cilindro idraulico

1

secondo norma di fabbricazione
Balluff

6

Dati tecnici

I valori  tipici per DC 24 V e 25 °C. Immediatamente pronto per il funzionamento, completa precisione dopo fase di
riscaldamento. In connessione con datore di posizione BTL-P-1013-4R, BTL-P-1013-4S o BTL-P-1012-4R:

6.1

Dimensioni, pesi, ambiente

Campo di misura

< 4000 mm

Dimensioni

 figura 3-2

Peso

circa 2 kg/m

Scatola

acciaio inox

Tubo di protezione

acciaio inox 1.4571

Diametro

10,2 mm

Spessore parete

     2 mm

Modulo E

circa 200 kN/mm

2

Fissaggio custodia 6 viti cilindriche

ISO 4762 – M6 × 16 – A2-70

Temperatura d’esercizio

da –40 °C sino a +85 °C

Umidità < 90 %, non condensante
Grado di protezione secondo IEC 529
(connettore avvitato)
versione con connettore:

IP 67

versione con cavo:

IP 68

(omologazione 5 bar / 48 h)

6.2

Alimentazione elettrica

(esterna)

Tensione stabilizzata
BTL5-_1... DC 20 sino a 28 V
Ondulazione residua    < 0,5 V

pp

Assorbimento di
corrente

< 150 mA

Corrente massima di
avviamento

< 3 A/0,5 ms

Protezione contro inversione delle
polarità

installata

Protezione contro la sovratensione
Diodi Zener di protezione
Rigidità dielettrica messa a terra
verso la scatola

500 V

6.3

Uscite

BTL5-A11...

Tensione di uscita 0...10/10...0 V
Corrente di carico

< 5 mA

Ondulazione residua

< 5 mV

BTL5-G11...

Tensione di uscita –10...10/10... –10 V
Corrente di carico

< 5 mA

Ondulazione residua

< 5 mV

BTL5-C1_...

Tensione di uscita  0...20/20...0 mA
Resistenza di carico

 < 500 Ohm

BTL5-E1_...

Tensione di uscita  4...20/20...4 mA
Resistenza di carico

 < 500 Ohm

6.4

Connessione all’unità
elettronica

Interfaccia analogica
Cavo schermato (lunghezza max.
vedi connessioni), Ø 6 ... 8 mm

6.5

Elementi compresi nella
fornitura

Trasduttore di posizione

 fig. 3-2

6.6

Datori di posizione

(da ordinare separatamente)

Datori di posizione
BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R

Dimensioni

 fig. 3-4

Peso

ca. 10 g

Scatola

alluminio anodizzato

Temperatura d’esercizio

da –40 °C sino a +85 °C

Datori di posizione BTL5-P-4500-1

(elettrocalamita)
Peso

ca. 90 g

Scatola

materiale plastico

Temperatura d’esercizio

da –40 °C sino a +60 °C

6.7

Accessori 

(optional)

Connettori

 fig. 4-3

N. 814 511 I  

  Edizione 0108;  Si riserva il diritto di apportar

e modifiche  

  Sostituisce l'edizione 9812.

7

Versioni (dati sulla targhetta di fabbrica)

Alimentazione 1 = DC 24 V

Tipo di connessione, SR 32: con connettore,

BTL5-A11-M0450-K-SR 32

K05: a cavo lungo 5 m

Versione a barra,
Fissaggio:

6 viti ISO 4762 – M6 × 16 – A2-70

Campo di misura (4 caratteri):M = sistema metrico in mm

U = sistema in 1/10 pollici

Interfaccia analogica:
tensione in uscita A11 = 10 ... 0 V e 0 ... 10 V

G11 = 10 ... –10 V e –10 ... 10 V

corrente in uscita C10 = 0 ... 20 mA

E10 = 4 ... 20 mA

C17 = 20 ... 0 mA

E17 = 20 ... 4 mA

T

rasduttor

e di

posizione 

Micr

opulse

Summary of Contents for BTL5-A11 series

Page 1: ...ecniche Manuale d uso Descripci n t cnica Manual de instrucciones deutsch english fran ais italiano espa ol Balluff GmbH Schurwaldstra e 9 73765 Neuhausen a d F Deutschland Telefon 49 0 71 58 1 73 0 T...

Page 2: ......

Page 3: ...utsch Balluff GmbH Schurwaldstra e 9 73765 Neuhausen a d F Deutschland Telefon 49 0 71 58 1 73 0 Telefax 49 0 71 58 50 10 Servicehotline 49 0 71 58 1 73 3 70 E Mail balluff balluff de http www balluff...

Page 4: ...64 Apparatus and Method for Auto matically Tuning the Gain of an Amplifier Emissionspr fungen Funkst rstrahlung EN 55011 Gruppe 1 Klasse A St rfestigkeitspr fungen Statische Elektrizit t ESD EN 61000...

Page 5: ...ieht mit hoher Pr zision und Reproduzier barkeit innerhalb des als Nennl nge angegebenen Messbereichs Am Stabende befindet sich die D mpfungszone ein messtechnisch nicht nutzbarer Bereich der berfah r...

Page 6: ...ungsbohrungen mit Zylinderschrauben ISO 4762 M6 x 16 A2 70 anzuschrauben Bild 3 2 Alle Schrauben m s sen mit 3 5 Nm festgedreht wer den Bei waagerechter Montage von Wegaufnehmern mit Nennl ngen gr er...

Page 7: ...Netzoberwel len z B von Phasenanschnittsteue rungen f r die der Kabelschirm nur geringen Schutz bietet L nge des Kabels max 20 m 6 bis 8 mm L ngere Kabel sind einsetzbar wenn durch Aufbau Schirmung u...

Page 8: ...rch falsche Verbindungen und berspannung besch digt werden Bevor Sie einschalten pr fen Sie deshalb die Anschl sse sorgf ltig 5 2 Null und Endpunkt einstellen Um den BTL Wegaufnehmer an die Erforderni...

Page 9: ...t ver bundenen Komponenten ist regel m ig zu berpr fen und zu protokollieren 5 6 Funktionsst rung Wenn Anzeichen erkennbar sind dass das Wegmesssystem nicht ordnungsgem arbeitet ist es au er Betrieb z...

Page 10: ...Kabelausf hrung IP 68 Typpr fung 5 bar 48 h 6 2 Stromversorgung extern Spannung stabilisiert BTL5 _1 DC 20 bis 28 V Restwelligkeit 0 5 Vss Stromaufnahme 150 mA Einschaltspitzenstrom 3 A 0 5 ms Verpol...

Page 11: ...nglish Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 Servicehotline 49 0 71 58 1 73 3 70 E Mail balluff balluff de http www balluff de http...

Page 12: ...connection with this product US Patent 5 923 164 Apparatus and Method for Auto matically Tuning the Gain of an Amplifier Emission tests RF Emission EN 55011 Group 1 Class A Noise immunity tests Stati...

Page 13: ...ar acteristic This process takes place with measuring high precision and repeatability within the stroke range defined as nominal stroke length At the rod end is a damping zone within which no reliabl...

Page 14: ...ounting attach the transducer with all 6 cylinder head screws ISO 4762 M6 x 16 A2 70 Fig 3 2 All screws must be tightened to 3 5 Nm For horizontal mounting of trans ducer with stroke lengths greater t...

Page 15: ...hase control devices against which the cable shield provides only limited protection Cable length max 20 m 6 to 8 mm Longer lengths may be used if construction shielding and routing are such that exte...

Page 16: ...ble check your connections 5 2 Set null and span Should mounting conditions require it the factory set null and or end point for the magnet can be shifted by a total of max 15 of the full nominal stro...

Page 17: ...its associated com ponents should be regularly checked and recorded 5 6 Fault conditions When there is evidence that the transducer system is not operating properly it should be taken out of service...

Page 18: ...29 with connector attached connector version IP 67 cable version IP 68 type tested at 5 bar 48 h 6 2 Supply voltage external Regulated supply voltage BTL5 _1 DC 20 to 28 V Ripple 0 5 Vpp Current draw...

Page 19: ...an ais Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F R F A T l phone 49 0 71 58 1 73 0 T l copieur 49 0 71 58 50 10 Servicehotline 49 0 71 58 1 73 3 70 E Mail balluff balluff de http www ballu...

Page 20: ...of an Amplifier Contr les de l mission Rayonnement parasite EN 55011 groupe 1 classe A Contr les de la r sistance au brouillage Electricit statique ESD EN 61000 4 2 degr d intensit 3 Champs lectromag...

Page 21: ...t lev e l int rieur de la plage de mesure correspondant la longueur nominale La zone d amortissement est situ e l extr mit de la tige et ne peut tre utilis e des fins de mesure Le capteur peut toutefo...

Page 22: ...que ISO 4762 M6 16 A2 70 Fig 3 2 Toutes les vis doivent tre serr es au couple de 3 5 Nm En cas de montage horizontal de capteurs de d placement dont la longueur nominale d passe 500 mm il est recomman...

Page 23: ...teur reliez le blindage au bo tier du connecteur multibroches BKS l int rieur de ce dernier fi gure 4 3 voir notice dans l em ballage du connecteur multibroches Dans le mod le raccordement fixe le bli...

Page 24: ...nt la mise sous ten sion 5 2 R glage du point d origine et de la fin de course Pour adapter le BTL aux exigences propres l installation il est possi ble de modifier la position de d part et ou de fin...

Page 25: ...f rents doit tre v rifi e r guli re ment et consign e 5 6 D faillance Lorsque des indices de dysfonc tionnement du syst me de mesure de d placement sont d cel s celui ci doit tre mis hors service et l...

Page 26: ...marrage 3 A 0 5 ms D trompage incorpor Limiteur de tension Diodes de protection Transzorb Rigidit di lectrique GND contre le bo tier 500 V 6 3 Sorties BTL5 A11 Tension de sortie 0 10 10 0 V Courant d...

Page 27: ...iano Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germania Telefono 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 Servicehotline 49 0 71 58 1 73 3 70 E Mail balluff balluff de http www balluff de ht...

Page 28: ...gnati i seguenti brevetti US Patent 5 923 164 Apparatus and Method for Auto matically Tuning the Gain of an Amplifier Collaudi emissioni Irradiazione di disturbi radio EN 55011 Gruppo 1 Classe A Colla...

Page 29: ...istica crescente o decrescente garan tita una precisione e riproducibilit elevata all interno del campo di misura Alla fine della barra si trova la zona di smorzamento non utilizzabile ai fini metrolo...

Page 30: ...con su tutti e 6 i fori con viti cilindriche ISO 4762 M6 x 16 A2 70 Figura 3 2 Tutte le viti devono essere strette a 3 5 Nm In caso di montaggio orizzontale di trasduttori con campi di misura superior...

Page 31: ...spina BKS figu ra 4 3 con l alloggiamento con nettore vedi le istruzioni compre se nel materiale di fornitura del connettore a spina Nella versione a cavo lo schermo del cavo collegato all alloggia me...

Page 32: ...en dere il trasduttore controllare con cura le connessioni 5 2 Impostazione zero e fondo scala Per adattare il BTL alle esigenze possibile spostare il valore iniziale e o finale del datore di posizion...

Page 33: ...di tutte le componenti ad esso connesse deve essere periodi camente verificato e protocollato 5 6 Difetti di funzionamento Qualora si individuino segnali che facciano presumere un funziona mento non...

Page 34: ...entazione elettrica esterna Tensione stabilizzata BTL5 _1 DC 20 sino a 28 V Ondulazione residua 0 5 Vpp Assorbimento di corrente 150 mA Corrente massima di avviamento 3 A 0 5 ms Protezione contro inve...

Page 35: ...es espa ol Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Alemania Tel 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 L nea de servizio 49 0 71 58 173 370 E Mail balluff balluff de http www balluff de...

Page 36: ...es US Patent 5 923 164 Apparatus and Method for Auto matically Tuning the Gain of an Amplifier Pruebas de emisiones Radiaci n con interferencias radiof nicas EN 55011 Grupo 1 clase A Pruebas de inmuni...

Page 37: ...medida indicado como longitud nominal En el extremo final de la varilla se encuentra la zona de amortiguaci n una zona que no puede aprovecharse para medida y que puede rebasarse La conexi n el ctrica...

Page 38: ...los 6 agujeros de fijaci n con tornillos cil ndricos ISO 4762 M6 x 16 A2 70 Figura 3 2 Todos los tornillos deben apretarse a 3 5 Nm En el montaje horizontal de trans ductores de desplazamiento con lo...

Page 39: ...externos En el modelo enchufable la panta lla tiene que unirse a la carcasa del conector dentro del conector BKS figura 4 3 v anse las instruc ciones en el embalaje del conector En el modelo de cable...

Page 40: ...efectuar la conexi n compruebe detenidamen te las conexiones 5 2 Ajuste del punto cero y del punto final Para adaptar el transductor de des plazamiento BTL a los requisitos la posici n inicial o fina...

Page 41: ...omponentes asociados a ste debe verificarse peri dicamente y reflejarse en un protocolo 5 6 Anomal a funcional Si existen indicios de que el sistema de medici n de desplazamiento lineal no funciona de...

Page 42: ...or IP 67 Versi n con cable IP 68 Homologaci n 5 bar 48 h 6 2 Alimentaci n el ctrica externa Tensi n estabilizada BTL5 _1 DC 20 hasta 28 V Rizado 0 5 Vpp Intensidad absorbida 150 mA Intensidad pico de...

Reviews: