![Balluff BSP B S1A-S4 Series User Manual Download Page 10](http://html1.mh-extra.com/html/balluff/bsp-b-s1a-s4-series/bsp-b-s1a-s4-series_user-manual_4038748010.webp)
2
english
BSP B/M/V _ _ _ - _ _ _ _ _ - _ _ _ S1A - S4(- _ _ _ )
Pressure Transmitter IO-Link
Installation (continued)
Installation for connections per DIN 3852
Check before installation:
– Does the sealing surface have a flawless surface?
– Is any residue present?
– Is the O-ring seated and in perfect condition in the
provided groove?
►
Tighten the device by hand in the holding threads. Use
an appropriate open-end wrench to tighten and
observe the following tightening torques:
Torque 1/4"
Connec-
tion per
DIN 3852
Connec tion
per
DIN EN 837
NPT
connec-
tion
R-connec-
tion
approx.
5 Nm
approx.
20 Nm
approx.
30 Nm
approx.
30 Nm
Torque 1/2"
Connec-
tion per
DIN 3852
Connec tion
per
DIN EN 837
NPT
connec-
tion
R-connec-
tion
approx.
10 Nm
approx.
50 Nm
approx.
70 Nm
approx.
70 Nm
Electrical Connection
Only make the electrical connection with
pressure and power turned off.
Connect the device electrically according to the details on
the part label, the pin assignment table below and the
connection diagram.
Electrical
connections
SIO mode
IO-Link mode
Pin 1
Pin 2
n. c.
n. c.
Pin 3
Supply –
Supply –
Pin 4
PNP
IO-Link
Connection diagrams
PNP