www.balluff.com
47
english
6
Secondary Device Functions
6.1
External Signal Blanking
6.1.1 Description
External signal blanking reduces the sensitivity to
interfering signals in the surrounding area. Interference is
filtered out.
If external signal blanking is active, an additional
measurement is performed with the transmitter switched
off. This allows external light interference to be blanked
out. However, the measurement becomes slower and the
maximum possible switching frequency can decrease.
6.1.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
External Signal Blanking
0x0421 (1057)
0
R/W
1 byte
UINT8(ENUM)
Yes
0
Tab. 6-1: External signal blanking – ISDU
External Signal Blanking
The function can be activated and deactivated via the
External Signal Blanking
parameter.
Value
Meaning
Description
0x00 (0) Deactivated
External signal blanking off
0x01 (1) Activated
External signal blanking on
Tab. 6-2: External signal blanking – Activate/deactivate
6.1.3 System Commands
Command
Value
Device Action
0x81 (129)
Application Reset
– Resets writable
parameters to the default value.
0x82 (130)
Restore Factory Settings
– Resets
writable parameters to the default value.
Tab. 6-3: External signal blanking – System Commands
For an overview of all System Commands, see section 3.5
6.1.4 Variant Dependence
The functionality is available in all variants.
BOS R254K-UUI-RH11-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH11-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH11 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH11 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH11 S4 Configuration Guide english...
Page 110: ...www balluff com...