Balluff BOL 27K-PS/NS-01 Instruction Manual Download Page 3

 

This operation is necessary when objects, inside the operating area, must not be detected.  

Detection of the reflecting tape characteristics

 

Press contemporily the + and – push-buttons for at least 6s. 

-

 

The “TAPE” message appears. 

 

OUT A M1  M2  Dig1  Dig2 Dig3 Dig4  + 

SET 

„

 

…

 

„

 

…

 

{

 

z

 

{

 

 

 

 

 

 

{

 

{

 

{

 

 

-

 

The reflecting tape characteristics are memorised when the push-buttons are released (the 
“TAPE” message blinks for 2s, 4Hz) and the sensor returns to the normal mode. 

 

OUT A M1  M2  Dig1 Dig2 Dig3 Dig4  + 

SET 

„

 

…

 

„

 

…

 

4  

{

 

{

 

{

 

This operation is particularly suggested in the “AREA” operating mode as this mode is very sensitive 
to the reflecting tape characteristics. 
 

 

REMOTE FUNCTIONS 

KEYLOCK 

The keyboard block function is activated at powering on, connecting the SYNC terminal to the 
positive power supply (+Vdc) for at least 1 s, and the push-buttons are NO LONGER active. 
After the first second, the SYNC input is ready for the normal functioning and if the SYNC is passive 
the outputs are deactivated. 
To deactivate the 

keyboard block

, the sensor has to be turned off and re-powered maintaining the 

SYNC wire not connected or ground connected (GND). 
 

SYNC input 

The SYNC signal allows to determine precisely the beginning and end of the identification. 
The identification cycle begins after the transition of the SYNC signal from passive to active and the 
sensor outputs are updated after max. 8 ms. 
All the outputs are deactivated after max. 8 ms from the active – passive transition. 
 
The connection of the SYNC wire to +Vdc corresponds to the passive logic status while SYNC not 
connected or connected to 0 V corresponds to the active. 
 

 

If the SYNC input is active, at the receipt of the 

@ <CR> <LF> 

command, the sensor responds 

with: 

?? <CR> <LF>. 

At the receipt of the 

q <CR> <LF>

 or 

e <CR> <LF> 

commands, the sensor 

transmits 

ok <CR> <LF>.

 

 

NOTE: the single characters have to be distanced amongst themselves at least 1 ms, during 
the command transmission. 

 

 

DETECTION DIAGRAMS 

 

 
 

 

 

 

DECLARATION OF CONFORMITY 

We BALLUFF declare under our sole responsibility that these products are conform to the 89/336 
CEE, 73/23 CEE Directives and successive amendments.

 

BALLUFF warrants its products to be free from defects. 
BALLUFF will repair or replace, free of charge, any product found to be defective during the warranty 
period of 24 months from the manufacturing date.  
This warranty does not cover damage or liability deriving from the improper application of BALLUFF 
products.

 

 
BALLUFF GmbH

 

Schurwaldstrasse 9

 

 

73765 Neuhausen a.d.F. 

 Germany 
 

T49 (0) 71 58/1 73-0 

 

T49 (0) 71 58/50 10 

 E-Mail: 

[email protected]

 

„

 

www.balluff.com

Nr./No. 840 702D/E 
Ausgabe/Edition 01 0506 105545;  
Änderungen vorbehalten/Subject to modification

 

 