Balluff BOL 27K-PS-01 Instruction Manual Download Page 2

 

SETTING OF THE 2 THRESHOLDS 

The sensor setting is effected placing the object to detect directly in front of the sensor following the 
procedure given below: 

 

 

 

push-button pressed 

 

push-button not pressed 

 

 

LED on 

 

LED off 

 

Obect detection at OFF/ON output switching

 

-  Position  the  object  inside  the  measurement  area  to define the measurement value (depending 

on the operating mode used) corresponding to the OFF/ON switching of the digital output. 

 

 

 

Display 

Keyboard 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

Press the SET push-button for at least 2s.  

The  detected  value  for  the  first  switching  threshold  appears  (4Hz  blinking  until  the  SET  push-
button is released). 

-

 

The value acquired can be changed using the +/- push-buttons. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

  

4  

 

 

 

-

 

The units change if these push-buttons are pressed repeatedly, the tens if kept pressed.  

-

 

Press  the  SET  push-button  again  for  at  least  0.5  s.  to  end  the  detection  phase  of  the  first 
switching threshold. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

  

4  

 

 

 

 

Obect detection at ON/OFF output switching

 

-  Position the object inside the measurement area to define the measurement value (depending on 
the operating mode used) corresponding to the ON/OFF switching of the digital output. 

-

 

The detected value for the second switching threshold appears.

 

-

 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

-

 

The present value appears (4Hz blinking). 

-

 

Press the SET push-button again for at least 0.5 s. to detect the second switching threshold. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

  

6  

 

 

 

The detected value for the second switching threshold appears. 

-

 

The value acquired can be changed using the +/- push-buttons. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

  

6  

 

 

 

-

 

The units change if these push-buttons are pressed repeatedly, the tens if kept pressed.  

-

 

Press the SET push-button again for at least 0.5 s. to end the detection phase. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

  

6  

 

 

 

 

SWITCHING THRESHOLD ADJUSTMENT 

 

 

Display 

Keyboard 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

Press one of the +/- push-buttons for at least 2 s. 

-

 

The “tH-1” message appears. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

Switching threshold selection

 

-

 

Use the +/- push-buttons to select the switching threshold. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment phase of the switching threshold

 

-

 

Press the SET push-button for at least 0.5 s. 

-

 

The previously detected value appears. 

-

 

The value can be changed using the +/- push-buttons. 

-

 

The units change if these push-buttons are pressed repeatedly, the tens if kept pressed.  

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

6  

 

 

 

-

 

Press the SET push-button again for at least 0.5 s. to end the adjustment phase. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

4  

 

 

 

 

SETTING OF THE PARAMETERS 

 

 

Display 

Keyboard 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

  

 

 

 

 

Press the SET push-button for at least 6s to enter into the parameter setting mode. 

The "MEnu" message appears. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

-

 

Pressing the + and 

–push-buttons the user can run up and down the menu, reading the 

following messages. 

 

Functioning mode selection

 

 

-  At each pressure on the SET push-button the user can run through the options of the selected 

level. 

 

OUT 

M1   

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delay setting

 

-

  At each pressure on the SET push-button the user can run through the  options of the selected 

level.

 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 d 

 

 

 

-  The setting of the delay value is in common to both outputs.  
  When the delay value set is different from zero, the outputs will remain active for a minimum 

time equal to the number of milliseconds visualised on the display. 

Visualisation of the threshold 1 data 

-

 

Pressing the SET push-button the value of the threshold 1 appears. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

THRESHOLD

 

 

 

 

Visualisation of the threshold 2 data 

Pressing the SET push-button the value of the threshold 2 appears.

 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

THRESHOLD 

  

 

 

 

Visualsation of the operating area status 

-  Pressing the SET push-

button the operating area status. More precisely; if “FULL” the operating 

area is complete, if “REDU“ the acquired area is not complete, but presents some zones that do 
not have to be detected . 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

or 

 

 

 

 

 

 

 

 

Reset of the sensor default configuration 

-

 

Pressing the SET push-

button (the “RESE” message blinks for 2s, 4Hz) the default configuration 

is re-set and the user exits from the menu, returning to the normal mode. The default 
configuration is: “beg object” operating mode, delay 0, Th1 switching threshold = 100, Th2 = 
200. 

 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memorisation of the parameters set

 

-  Pressing the SET push-

button (the “SAVE” message blinks for 2s, 4Hz) all the modified values 

are memorised and the user exits form the menu,returning to the normal mode.  

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-  Press one of the +/- push-buttons the user can return to the setting menu. 

Exit from the parameter setting menu

 

After 10s inactivity of the sensor push-buttons, the sensor returns to the normal operating mode 
visualising the distance. 

 

ADVANCED FUNCTIONS 

 

 

Display 

Keyboard 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

Operating area selection

 

Press contemporarily the + and 

– push-buttons for at least 2s. 

-

 

The “W_Ar” message appears. 

 

OUT 

M1 

M2 

Dig1 

Dig2 

Dig3 

Dig4 

SET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

The operating area configuration is memorised when the push-buttons are released (the W_Ar 
blinks for 2s, 4Hz) and the sensor returns to the normal mode. 

 