Startup
DANGER
Uncontrolled system movement
When starting up, if the network module is part of a
closed loop system whose parameters have not yet been
set, the system may perform uncontrolled movements.
This could result in personal injury and equipment
damage.
►
Persons must keep away from the system’s
hazardous zones.
►
Startup must be performed only by trained technical
personnel.
►
Observe the safety instructions of the equipment or
system manufacturer.
1.
Check connections for tightness and correct polarity.
Replace damaged connections.
2.
Turn on the system.
Check for the correct values, especially after
replacing the BNI or after repair by the
manufacturer.
6.2
Operation
CAUTION
Danger of burns from hot surfaces
The housing heats up under normal operating conditions.
There is a risk of burn injuries.
►
Avoid direct skin contact with the surface.
Operating notes
– Regularly check function of the BNI and all associated
components.
– Take the sensor out of service whenever there is a
malfunction.
– Secure the system against unauthorized use.
– Check fasteners and retighten if needed.
6.3
Cleaning
For UL requirements, see chapter 8.7.2 on
page 14.
The product may only be cleaned when switched off.
6.4
Maintenance
The product is maintenance-free.
Depending on the operating conditions, it may be
necessary to regularly check and, if necessary, retighten
the tightening torques of the plugs and caps to maintain
the protection classes (see chapter 5.2 on page 9).