www.balluff.com
28
6
Display
6.7.
Factory Reset
•
Go through the Network Config menu with short-time keypress on Arrow-Key.
•
Reset the module with a long-time keypress on Set-Key at the Factory Reset menu
item.
•
Confirm the factory reset with a short-time keypress on Set-Key or decline it with a
short-time keypress on Arrow-Key. If the factory reset is confirmed, the device
performes a restart.
Note
A factory reset can be performed only after a power reset without an attached
network cable.
6.8.
Module Info
•
Go through the Module Info menu with short-time keypress on Arrow-Key.
•
You can select between the device name, the hard and software version and the
MAC-ID.
IP
192.168.
015.005
SUBNET
255.255.
255.000
GATEWAY
000 . 000.
000 . 000
PN NAME
Bnipnt508
105z031
FACTORY
RESET
e
d
iti
n
g
m
o
d
e
Pro
g
ra
m
m
ie
rm
o
d
u
s
S
PLEASE
CONFIRM
PERFORM-
ING
RESET…
S
BNI
PNT-508-
105-Z031
VERSION
HW: 1
SW: 1.1
MAC-ID:
00:19:31:
30:44:0A