www.balluff.com
12
4
Technical data
4.11.
Dimensions
BNI PNT-508-105-
Z031-004
4.12.
Mechanical
data
Housing material
Die-cast zinc, matte nickel-plated
Housing protection type in
accordance with IEC 60529
IP 67 (only in plugged-in and screwed-down state, and
depending on the connector system which is used.)
Dimensions (W x H x D in mm)
84.4 x 185.4 x 47
Type of installation
Screw installation with 2 securing holes
Ground strap installation
M4
Weight
Approx. 950 gr.
4.13.
Operating
conditions
Operating temperature T
a
Storage temperature
-5 °C ... 55 °C
-25 C ... 70 °C
EMC
- Immunität / Immunity
- Emission / Emission
EMC-directive 2004/108/EEC
- EN 61000-6-2
- EN 61000-6-4
Vibration/shock
EN 60068-2-6, EN 60068-2-27
EN 60068-2-29, EN 60068-2-64
4.14.
Electrical data
Supply voltage
18...30.2 V DC, in accordance with EN 61131-2
Ripple
<1%
Input current
220 mA @24V
4.15.
ProfiNet
PROFINET Port
1 x 10Base-/100Base-Tx
1 x 100Base Fx POF
Date transmission rate
100 mbit/s
Max. cable length
50 m
Flow control
Half Duplex/Full Duplex (IEEE 802.33x-Pause)