Balluff BNI PBS-504-002-K008 User Manual Download Page 2

Balluff Network Interface Profibus, BNI PBS-504-00x-K008 

 

   

1 Notes for the User 

1.1 

About this guide  

1.2 

Structure of the guide 

1.3 

Typografical conventions

 

1.3.1 

Enumerations 

1.3.2 

Actions 

1.3.3 

Syntax 

1.3.4 

Cross references 

1.4 

Symbols 

1.5 

Abbreviations 

 
2 Safety 

2.1 

Intended use  

2.2 

Installation and startup 

2.3 

General safety instructions

 

2.4 

Resistance to aggressive substances 

2.5 

Hazardous voltage 

 
3 Basis knowledge 

3.1 

Product description  

3.2 

Profibus

 

3.3 

IO-Link 

3.3 

Communication mode 

3.4 

Replacing modules 

 
3 Getting started 

3.1 

Connection overview front side

 

3.2 

Mechanical connection 

3.3 

Electrical connection 

3.3.1 

Power supply 

3.3.2 

Profibus interface 

3.4 

Connecting sensors / actuators 

10 

3.4.1 

Standard I/O ports 

10 

 

Technical data

 

4.1 

Dimensions front side 

11 

4.2 

Dimensions cutout back side 

11 

4.3 

Mechanical data 

11 

4.4 

Electrical data 

12 

4.5 

Operating conditions 

12 

4.6 

Function indicators 

13 

 
5 Included material 

5.1 

Included material 

14 

 
6 Appendix 

 

Ordercode / order information 

15 

 
 
 

Summary of Contents for BNI PBS-504-002-K008

Page 1: ...BNI PBS 504 001 K008 BNI PBS 504 002 K008 Profibus IO Link Panelmaster User s Guide...

Page 2: ...ltage 3 3 Basis knowledge 3 1 Product description 4 3 2 Profibus 4 3 3 IO Link 4 3 3 Communication mode 5 3 4 Replacing modules 5 3 Getting started 3 1 Connection overview front side 6 3 2 Mechanical...

Page 3: ...points Entry 1 Entry 2 1 3 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2...

Page 4: ...ed Personnel Installation and commissioning may only be performed by trained specialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized...

Page 5: ...of stations as well as for data communication per IEC 61158 EN 50170 Automation devices such as PLC s PC s control and monitoring devices sensors or actuators can ommunicate over this bus system Varia...

Page 6: ...output modules Deterministic time behavior Typically 2 ms cycle time 16 bits of process data and 38 4 Kbaud transmission rate Service data diagnostics parameters parallel and reactionless process data...

Page 7: ...ted 3 1 Connection overview Front side BNI PBS 504 00x 1 Input Output IO Link port 1 2 LED Input Output IO Link port 3 Input Output IO Link port 3 4 IO Link logo 5 Input Output IO Link port 2 6 Label...

Page 8: ...hanical connection The module BNI PBS 504 is attached using 4 M5x10 The thread insert for mounting the module is 8mm 1 Mounting holes with 8mm thread insert 2 Ground connection 3 Power supply interfac...

Page 9: ...on Sensor supply 5 24V Bus communication Sensor supply 4 0V Bus communication Sensor supply 3 0V Bus communication Sensor supply 2 24 V DC max 12 A AUX AUX Power 1 0V AUX GND AUX Power Pin 1 and 2 int...

Page 10: ...minator 7 Not connected 8 B line 9 Not connected Connecting the Profibus Continuation of the Profibus by SUB D9 Pin connectors Note Each Profibus segment end must be installed with a termination resis...

Page 11: ...ur I O ports are provided for connecting the actuators sensors for Standard I O and or IO Link 3 4 1 IO Link port PIN IO Link port M12 A coded female 1 24 V DC 1 4 A 2 AUX power 24 V 3 0 V 4 IO Link I...

Page 12: ...ts standard cutout type 24 4 3 Mechanical data Housing material Plastic Fieldbus Profibus SUB D 9 Pin female Supply power Terminal plugs spring type on the backside AUX power supply Terminal plugs spr...

Page 13: ...0 V DC Operation voltage AUXPower 18 30 V DC 12A no internal fuse external protection requested Ripple 1 Current draw without load 200 mA 4 5 Operating conditions Operating temperature Storage tempera...

Page 14: ...D 2 Green AUX power supply connected LED 3 Green solid Green blinking BUS Data transmission active BUS Data transmission inactive I O IO Link ports Each M12 Port digital input output is assigned to LE...

Page 15: ...f Network Interface Profibus BNI PBS 504 00x K008 www balluff com 14 5 Included material 5 1 Included material The BNI PBS consists of the following components IO block 2 blind plugs M12 20 labels 1 g...

Page 16: ...rfaces Pin 4 4x AUX power interfaces Variants 000 Standard version 001 Software release 001 002 IO Link specification 1 1 Mechanical version K008 panel mount master housing Profibus port Sub D 9 Pin P...

Page 17: ...Balluff Network Interface Profibus BNI PBS 504 00x K008 www balluff com 16...

Page 18: ...PBS 504 00x K008 www balluff com 17 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 883191 EN Edition E15 Replac...

Reviews: