background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

                                                

 

BNI PBS-504-001-K008 

BNI PBS-504-002-K008 

Profibus IO-Link Panelmaster 

User´s Guide 

 
 

Summary of Contents for BNI PBS-504-002-K008

Page 1: ...BNI PBS 504 001 K008 BNI PBS 504 002 K008 Profibus IO Link Panelmaster User s Guide...

Page 2: ...ltage 3 3 Basis knowledge 3 1 Product description 4 3 2 Profibus 4 3 3 IO Link 4 3 3 Communication mode 5 3 4 Replacing modules 5 3 Getting started 3 1 Connection overview front side 6 3 2 Mechanical...

Page 3: ...points Entry 1 Entry 2 1 3 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2...

Page 4: ...ed Personnel Installation and commissioning may only be performed by trained specialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized...

Page 5: ...of stations as well as for data communication per IEC 61158 EN 50170 Automation devices such as PLC s PC s control and monitoring devices sensors or actuators can ommunicate over this bus system Varia...

Page 6: ...output modules Deterministic time behavior Typically 2 ms cycle time 16 bits of process data and 38 4 Kbaud transmission rate Service data diagnostics parameters parallel and reactionless process data...

Page 7: ...ted 3 1 Connection overview Front side BNI PBS 504 00x 1 Input Output IO Link port 1 2 LED Input Output IO Link port 3 Input Output IO Link port 3 4 IO Link logo 5 Input Output IO Link port 2 6 Label...

Page 8: ...hanical connection The module BNI PBS 504 is attached using 4 M5x10 The thread insert for mounting the module is 8mm 1 Mounting holes with 8mm thread insert 2 Ground connection 3 Power supply interfac...

Page 9: ...on Sensor supply 5 24V Bus communication Sensor supply 4 0V Bus communication Sensor supply 3 0V Bus communication Sensor supply 2 24 V DC max 12 A AUX AUX Power 1 0V AUX GND AUX Power Pin 1 and 2 int...

Page 10: ...minator 7 Not connected 8 B line 9 Not connected Connecting the Profibus Continuation of the Profibus by SUB D9 Pin connectors Note Each Profibus segment end must be installed with a termination resis...

Page 11: ...ur I O ports are provided for connecting the actuators sensors for Standard I O and or IO Link 3 4 1 IO Link port PIN IO Link port M12 A coded female 1 24 V DC 1 4 A 2 AUX power 24 V 3 0 V 4 IO Link I...

Page 12: ...ts standard cutout type 24 4 3 Mechanical data Housing material Plastic Fieldbus Profibus SUB D 9 Pin female Supply power Terminal plugs spring type on the backside AUX power supply Terminal plugs spr...

Page 13: ...0 V DC Operation voltage AUXPower 18 30 V DC 12A no internal fuse external protection requested Ripple 1 Current draw without load 200 mA 4 5 Operating conditions Operating temperature Storage tempera...

Page 14: ...D 2 Green AUX power supply connected LED 3 Green solid Green blinking BUS Data transmission active BUS Data transmission inactive I O IO Link ports Each M12 Port digital input output is assigned to LE...

Page 15: ...f Network Interface Profibus BNI PBS 504 00x K008 www balluff com 14 5 Included material 5 1 Included material The BNI PBS consists of the following components IO block 2 blind plugs M12 20 labels 1 g...

Page 16: ...rfaces Pin 4 4x AUX power interfaces Variants 000 Standard version 001 Software release 001 002 IO Link specification 1 1 Mechanical version K008 panel mount master housing Profibus port Sub D 9 Pin P...

Page 17: ...Balluff Network Interface Profibus BNI PBS 504 00x K008 www balluff com 16...

Page 18: ...PBS 504 00x K008 www balluff com 17 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 883191 EN Edition E15 Replac...