Balluff / IO-Link BNI IOL-802-000-Z03x 
 

www.balluff.com 

   

   

 

24 

IO-Link Interface 

 

Blinking 
frequency / 
Runlight 
speed 
52

hex

 

  The frequency of the blinking in segment mode and the speed of the running segment in 

runlight mode can be set in this register. Values between 1 and 5 are accepted. One means the 
slowest and five means the fastest blinking or running speed. 

 

 

 

 

Note 

The blinking frequency is only valid for 50% duty cycle blinking. The frequency of the 
flashing cannot be changed.

 

 

 

Blinking 
mode 53

hex

 

 

Byte 

Bit 

D

es

cri

pt

ion

 

S

eg

men

t 5

 flas

hing

 

S

eg

men

t 4

 flas

hing

 

S

eg

men

t 3

 flas

hing

 

S

eg

men

t 2

 flas

hing

 

S

eg

men

t 1

 flas

hing

 

 
The segment X flashing bit sets the mode of the blinking. 
 
0 - blinking with 50% duty cycle 
1 - flashing 

 

 

 

 

Note 

Through this register only the mode of the blinking can be set (either 50% duty cycle or 
flash). The blinking of the desired segment must be activated in process data to 
enable blinking.

 

 

 

Flexible 
mode, LEDxx 
settings 
A1

hex

B4

hex

 

 

 

 

This register contains the settings for the flexible LEDs. Values from 0x00 to 0xFF are accepted 
for each setting. This register can be accessed through the subindices 0, 1, 2, 3, 4 or 5. 
Reading/writing the subindex 0 the whole 5 byte data can be accessed. Subindex 1, 2 and 3 
contains the red, green and blue color component, subindex 4 is the ON brightness and 
subindex 5 is the OFF brightness. 

 

 

 

 

Note 

These registers are available from software version 3.0. 
The Brightness ISDU register (51

hex

) determines the maximum brightness of each 

channel. It is recommended to set the Brightness ISDU register's value to 7F7F7F

hex

 

in case of using flexible mode.

 

 

 

 

 

Byte 

Sub 

Index 

D

es

cri

pt

ion

 

LED color, red 

channel 

LED color, 

green channel 

LED color, blue 

channel 

On brightness 

Off brightness 

 

Summary of Contents for BNI IOL-802-000-Z036

Page 1: ...BNI IOL 802 000 Z036 BNI IOL 802 000 Z036 006 BNI IOL 802 000 Z037 BNI IOL 802 000 Z037 006 Smart Light User s Guide...

Page 2: ...Runlight mode 11 3 11 Flexible mode 12 3 12 Synchronisation 12 4 IO Link Interface 13 4 1 IO Link Data 13 4 2 Process data Output data 13 BNI IOL 802 000 Z03x Segment Mode 13 Bit definitions in segme...

Page 3: ...hex 25 Limit type FDhex 25 Buzzer type FEhex 25 4 4 Errors 25 4 5 Events 25 5 Technical Data 26 5 1 Dimensions 26 5 2 Mechanical data 26 5 3 Electrical data 27 5 4 Operating conditions 27 5 5 LED indi...

Page 4: ...tion result Action instruction 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross referenc...

Page 5: ...arranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this operating manu...

Page 6: ...gment 4 6 Segment 5 7 Socket 8 M12 connector 9 M18 thread for mounting 10 Status LED 11 LED20 12 LED19 13 LED18 14 LED17 15 LED16 16 LED15 17 LED14 18 LED13 19 LED12 20 LED11 21 LED10 22 LED09 23 LED0...

Page 7: ...gment 2 4 Segment 3 5 Segment 4 6 Segment 5 7 Socket 8 M12 connector 9 M18 thread for mounting 10 Status LED 11 LED20 12 LED19 13 LED18 14 LED17 15 LED16 16 LED15 17 LED14 18 LED13 19 LED12 20 LED11 2...

Page 8: ...ground to FE terminal if present Connect the incoming IO Link line to the Smart Light Note A standard 3 wire sensor cable is used for connecting to the host IO Link master Module versions Version Desc...

Page 9: ...ery second The type of the blinking can be set in ISDU register The frequency of the normal blinking can be changed through an ISDU register 3 9 Level mode To use the signal light as a level meter the...

Page 10: ...tarted The LED bar at increasing input data and no color dominance The virtual segments can be seen on the left side Of course the segment 2 or 4 does not have to be the same color as segment 3 or 5 S...

Page 11: ...Balluff IO Link BNI IOL 802 000 Z03x www balluff com 10 3 Getting Started The LED bar at increasing input data all the colors are dominant Seg 1 Seg 2 Seg 3 Seg 4 Seg 5...

Page 12: ...or dominance The limits of the segments are modified so they are not equally distributed Of course segment 3 4 and 5 could have different colors too Seg 1 Seg 2 Seg 3 Seg 4 Seg 5 3 10 Runlight mode To...

Page 13: ...buzzer of several Balluff SmartLights The function is available in runlight and segment mode The synchronisation is controlled by 2 bits in the process data Sync Start and Sync Impluse When a rising e...

Page 14: ...nt Mode Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Segment 2 blink Segment 2 color Segment 1 blink Segment 1 color Segment 4 blink Segment 4 color Segment 3 blink Segment 3 color Byte 2...

Page 15: ...it level value LSB Byte 2 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync impulse Sync start Bit definitions in level mode Level value The 8 10 12 14 or 16 bit value for level indicator The resoluti...

Page 16: ...0 Description Byte 2 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync impulse Sync start Bit definitions in runlight mode Bit 7 Buzzer state Only in case of BNI IOL 802 000 Z037 0 buzzer is off 1 bu...

Page 17: ...15 state LED14 state LED13 state LED12 state LED11 state LED10 state LED09 state Byte 2 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync impulse Sync start LED20 state LED19 state LED18 state LED17 s...

Page 18: ...t 15 Byte www balluff com 12hex 0 Product name 20 Byte 24 Byte BNI IOL 802 000 Z036 BNI IOL 802 000 Z036 006 BNI IOL 802 000 Z037 BNI IOL 802 000 Z037 006 13hex 0 Product ID 7 Byte BNI007F BNI0072 14h...

Page 19: ...mode segment 4 color 1 Byte 0hex Fhex 1hex 48hex 0 Level mode segment 5 color 1 Byte 0hex Fhex 1hex 49hex 0 Level mode limit 1 2 2 Byte 0hex FFFFhex 80 4Ahex 0 Level mode limit 2 3 2 Byte 0hex FFFFhex...

Page 20: ...gs 5 Byte 0hex FFFFFFFFFFhex 00FF00FF01hex ABhex 0 1 5 LED11 settings 5 Byte 0hex FFFFFFFFFFhex 00FF00FF01hex AChex 0 1 5 LED12 settings 5 Byte 0hex FFFFFFFFFFhex 00FF00FF01hex ADhex 0 1 5 LED13 setti...

Page 21: ...e is configured to have 3 segments 1 1 LED is always switched of between the segments Level type 42hex The type of the level indicator 0 bottom up 1 top down Level resolution 43hex The resolution of t...

Page 22: ...s set to absolute value an 8 10 12 14 16 bit number depends on the resolution determines the limits between two segments in level mode The limit values are always right justified Byte 0 1 Bit 7 6 5 4...

Page 23: ...ser defined 111 White color is available from software version 2 1 Runlight mode running color 4Ehex Byte 0 Bit 7 6 5 4 3 2 1 0 Description Running color The color of the running segment in runlight m...

Page 24: ...This register sets the brightness for each channel red green and blue Values from 0x00 to 0x7F are accepted for each channel This register can be accessed through the subindices 0 1 2 or 3 Reading wr...

Page 25: ...the blinking can be set either 50 duty cycle or flash The blinking of the desired segment must be activated in process data to enable blinking Flexible mode LEDxx settings A1hex B4hex This register c...

Page 26: ...an absolute value The Limit type register sets the type of the evaluation 0x00 Limit type is given in a percent value 0x01 Limit type is given in an absolute value Note This register is available from...

Page 27: ...housing BNI IOL 802 000 Z03x 006 Polycarbonate transparent die cast zinc housing with chrome finishing IO Link Port M12 A coded male Enclosure rating BNI IOL 802 Z036 xxx IP65 only when plugged in BN...

Page 28: ...4V BNI IOL 802 000 Z037 xxx 410 mA 24V Volume of the buzzer module 100dB at 1m distance Tone frequency of the buzzer module 2800 500 Hz Total number of signal lights all 3 pages 3 x 20 5 4 Operating c...

Page 29: ...green flashing Status for supply and communication The status LED indicates the current status of the power supply and the communication It can be switched on switched of and flashing Communication er...

Page 30: ...e following components signal light M18x1 nut rubber foot screw M4 spring washer user s guide BNI IOL 802 000 Z03x xxx Balluff Networking Interface IO Link Interface 802 Smart Light 5 Segment Standard...

Page 31: ...Balluff IO Link BNI IOL 802 000 Z03x www balluff com 30 Notes...

Page 32: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 915905 726 EN 05 123333 Edition L16 Replaces Edition B15 Subject...

Reviews: