Safety 

2.1.  Intended use 

  The BNI IOL-… acts as a decentralized input/output sensor module, which is connected to a 

higher-level IO-Link master module through an IO-Link interface. 

 

2.2.  Installation and 

Startup 

 

 

Attention! 

Installation and startup must only be carried out by trained technical personnel. 
Qualified personnel are people who are familiar with installation and operation of 
the product and have the necessary qualifications for these tasks. Any damage 
resulting from unauthorized tampering or improper use voids the manufacturer's 
guarantee and warranty. The operator must ensure that appropriate safety and 
accident prevention regulations are observed. 

 

 

2.3.  General Safety 

Notes 

 

Commissioning and inspection 

Before commissioning, carefully read the user's guide. 
The system must not be used in applications in which the safety of persons is dependent 
upon proper functioning of the device. 

Authorized personnel 

Installation and startup must only be carried out by trained technical personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this user's 
guide 

Obligations of the operating company 

The device is a piece of equipment in accordance with EMC Class A. This device can 
produce RF noise. The operator must take appropriate precautionary measures. The device 
may only be used with an approved power supply. Use only approved cables. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 
Intended use is ensured only when the housing is fully installed. 

 

2.4. Resistance to 

Aggressive 
Substances 

 

 

Attention! 

The BNI modules always have good chemical and oil resistance. When used in 
aggressive media (such as chemicals, oils, lubricants and coolants, each in a 
high concentration (i.e. too little water content)), the material must first be 
checked for resistance in the particular application. No defect claims may be 
asserted in the event of a failure or damage to the BNI modules caused by such 
aggressive media.

 

 

 

 

Dangerous 
voltage 

 

 

Attention! 

Before maintenance, disconnect the device from the power supply. 

 

 

 

 

 

Note 

In the interests of product improvement, Balluff GmbH reserves the right to 
change the technical data of the product and the content of this manual 
at any time without notice. 

 

 
 

Summary of Contents for BNI IOL-309-002-Z019

Page 1: ...BNI IOL 309 002 Z019 IO Link 1 1 sensor actuator hub with extension port User s Guide...

Page 2: ...General Configuration 9 4 1 Extension port 9 Extension port configuration 55hex 9 Setting the serial number 54hex 9 5 Configuration Extension Off 10 5 1 IO Link Data 10 5 2 Process Data Input 10 5 3...

Page 3: ...ion 22 8 4 Resetting to Factory Settings 22 9 Technical Data 23 9 1 Dimensions 23 9 2 Mechanical Data 23 9 3 Electrical Data 23 9 4 Operating conditions 23 10 Function Indicators 24 10 1 Function Indi...

Page 4: ...with an dash Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2...

Page 5: ...proper use Use installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class...

Page 6: ...rview Figure 3 1 Connection overview BNI IOL 309 002 Z019 1 Ground connection 2 Mounting hole 3 Status LED communication 4 Label 5 Port 1 6 Port 3 7 Port 5 8 Port 7 extension port 9 Pin Port LED signa...

Page 7: ...ound The modules are equipped with a ground connection Figure 3 3 BNI ground connection IOL 309 Connect the sensor hub module to the ground connection Note The functional ground connection from the ho...

Page 8: ...port BNI IOL 309 002 Z019 IN OUT Sensor actuator interface Standardl input output port M8 Pin Function IN OUT 1 24V 4 In Out 3 0V Note For the digital inputs the input guideline specified in EN 61131...

Page 9: ...L 309 002 Z019 0 BNI IOL 309 002 Z019 with BNI IOL 102 002 Z019 1 Note The Factory reset command does not affect the configuration of the extension port in any way Note The process data length depends...

Page 10: ...1 byte output 5 2 Process Data Input Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port...

Page 11: ...text 16 bytes sensor actuator hub M8 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Parameter Data Demand Data...

Page 12: ...n Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port 0 Pin 4 Direction port x 0 Input 1 Output Safe state of Outputs 42hex The safe...

Page 13: ...www balluff com 13 5 Configuration Extension Off Value Output state bin dec 00 0 Output is 0V 01 1 Output is 24V 10 2 Current status is maintained 11 3 Not defined...

Page 14: ...Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1 Short circuit Port 1 Pin 1 Short circuit Port 0 Pin 1 Outputs off UA too low Undervoltage UA Undervoltage US Monitorin...

Page 15: ...e input 1 byte output 6 2 Process Data Input Data Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin...

Page 16: ...com 16 6 Configuration extended with BNI IOL 102 002 Z019 6 3 Process Data Output Data Byte 0 Bit 7 6 5 4 3 2 1 0 Description Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3...

Page 17: ...BNI0099 14hex 0 Product text 16 bytes M12 sensor actuator hub 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Par...

Page 18: ...0 Pin 4 Byte 1 Bit 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 20 19 18 17 Extension port Description Inversion Port 7 Pin 4 Inversion Port 6 Pin 4 Inversion Port 5 Pin 4 Inversion Port 4 Pin 4 Inversion Po...

Page 19: ...each output adopts the configured status The following statuses can be configured for each pin Safe state of the outputs on Pin 4 42hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1...

Page 20: ...28 27 26 25 Extension port Description Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Short circuit Port 5 Pin 1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin...

Page 21: ...sion 1 0 Event code Description 0x5112 Low sensor voltage US 0x5114 Low actuator voltage UA 0x5410 Output stages 0x8DF0 Retry at the extension port 0x8DF1 Device lost at the extension port 0x8DF2 Wron...

Page 22: ...iguration is automatically transferred to the new device This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of dat...

Page 23: ...voltage 18 30 2 V DC corresponding to EN 61131 2 Ripple 1 Current consumption without load extension off 90 mA Load current PIN 1 max 200 mA temperature dependent Load current per output PIN 4 max 30...

Page 24: ...ww balluff com 24 10 Function Indicators 10 1 Function Indicators LED Indicators module status LED Status Function COM US UA Green Communication error Green flashing Communication ok Red Undervoltage...

Page 25: ...ircuit Off Input output signal 0 Extension port The table is valid if the extension port is active If the extension port is used as a standard I O then the description from Digital LED indicators for...

Page 26: ...r code BNI IOL 309 002 Z019 BNI0093 BNI IOL 309 002 Z019 Balluff Network Interface IO Link interface Functions 309 8 inputs outputs Variants 002 with IO Link 1 1 extension port Mechanical configuratio...

Page 27: ...www balluff com 27 Notes...

Page 28: ...com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 926029 726 E Edition I18 Replaces Edition E16 Subject to m...

Reviews: