Balluff BNI IOL-101-000-K018 User Manual Download Page 3

Balluff Network Interface / IO-Link  

 

 

 

 

 

 

 

 

 

 www.balluff.com 

   

 

 

1  Notes 

1.1.  Struture of the 

guide 

  The guide is organized so that the sections build on one another. 

Section 2: Basic safety information. 

……. 

 

1.2.  Typographical 

conventions 

  The following typographical conventions are used in this guide.  

 

Enumerations 

  Enumertions are shown in list form with bullet points: 

• 

Entry 1 

• 

Entry 2 

 

Actions 

  Action instructions are indicated by a preceding triangle. The result of an action is indicated 

by an arrow. 

  Action instruction 1 

  Action result 

  Action instruction 2 

 

Syntax 

  Numbers: 

Decimal numbers are shown without additional indicators (e.g. 123), 

Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex).  

 

Cross references 

  Cross references indicate where additional information on the topic can be found. 

 

1.3.  Symbols 

 

Note 

This symbol indicates general notes. 

 

 

 

Attention! 

This symbol indicates a security notice which most be observed. 

 

1.4.  Abbreviations 

  BNI        Balluff Network Interface 

I-Port     Standard input port 

DPP       Direct parameter page 

IOL        IO-Link 

EMC      Electromagnetic compatibility 

FE 

Function earth 

SPDU    Service Protocol Data Unit 

 

1.5.  Deviating views 

  Product views and illustrations in this user's guide may differ from the actual product. They 

are intended only as illustrative material. 

 

1.6.  Disposal 

 

 

This product falls under the the current EU Directive for WEEE, waste of 

electrical and electronic equipment for protecting you and the environment 

from possible hazards and responsible handling of natural resources. 

 

Dispose of the product properly and not as part of the normal waste stream. 

Observe the regulations of the respective country. Information can be 

obtained from the national authorities. Or return the product to us for 

disposal. 

 

Summary of Contents for BNI IOL-101-000-K018

Page 1: ...BNI IOL 101 000 K018 BNI IOL 102 000 K019 BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 User s Guide...

Page 2: ...connection 6 3 5 IO Link Interface 6 Connecting the sensor hub 6 Module versions 6 Sensorinterface 6 4 IO Link interface 7 4 1 IO Link data 7 4 2 Process data Output data 7 4 3 Process data Input data...

Page 3: ...on the topic can be found 1 3 Symbols Note This symbol indicates general notes Attention This symbol indicates a security notice which most be observed 1 4 Abbreviations BNI Balluff Network Interface...

Page 4: ...ialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions...

Page 5: ...IO Link interface 2 Mounting hole 3 Status LED Communication module 4 Standard input port 1 5 Standard input port 3 6 Standard input port 5 7 Standard input port 7 8 Mounting hole 9 Port LED Standard...

Page 6: ...IOL 102 000 K020 BNI IOL 102 S01 K020 1 IO Link interface 2 Mounting hole 3 Status LED Communication module 4 Standard input port 1 5 Standard input port 3 6 Mounting hole 7 Port LED Standard input po...

Page 7: ...Connecting the sensor hub Connection protection ground to FE terminal if present Connect the incoming IO Link line to the sensor hub Note A standard 3 wire sensor cable is used for connection to the h...

Page 8: ...al cycle time 2 5 ms Process data cycle time 2 5 ms at minimal cycle time Process data length 1 Byte BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 Data transmission rate COM2 38 4 kBaud Frame type 2 2 Min...

Page 9: ...e 0 Bit 7 6 5 4 3 2 1 0 Description Input port 3 pin 4 Input port 2 pin 4 Input port 1 pin 4 Input port 0 pin 4 BNI IOL 102 000 K019 8 binary inputs Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input port 7...

Page 10: ...in 4 Error port 1 pin 4 Error port 0 pin 4 BNI IOL 102 S01 K019 8 binary inputs with single channel monitoring Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Input port 7 pin 4 Input port 6...

Page 11: ...S01 K019 13hex 19 0 Product ID 7 Byte BNI000P BNI001W BNI000R BNI001Y 14hex 20 0 Product text 22 Byte Sensor Hub digital M8 4 inputs Sensor hub digital M8 4 inputs SPC Sensor hub digital M8 8 inputs S...

Page 12: ...e Type Instance Appears Error AL Device Hardware Supply Supply low voltage U2 Supply 24V 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0002 0xF3 0x5112 Disappears Error AL Device Hardware Supply Supply low vo...

Page 13: ...29 IP 67 only when plugged and threaded in Dimensions W x H x D in mm BNI IOL 101 000 K018 BNI IOL 101 S01 K018 30 x 85 x 24 BNI IOL 102 000 K019 BNI IOL 102 S01 K019 30 x 129 x 24 Weight BNI IOL 101...

Page 14: ...gure 5 3 LED indicators Module status LED 2 Communication module supply LED Indication Function LED 2 Green No communication supply ok Green negative pulsed Communication ok supply ok Red flashing Com...

Page 15: ...LED 1 I Port Pin 4 Indication Function Yellow static Input signal 1 Off Input signal 0 LED I ports with single channel monitoring BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 LED 1 I Port Pin 4 with sing...

Page 16: ...face and power supply 1xM12 external thread I ports 4xM8 female 3 pole K019 Plastic housing M8 8 port IO Link interface and power supply 1xM12 external thread I ports 8xM8 female 3 pole 6 2 Order info...

Page 17: ...Balluff Network Interface IO Link www balluff com 16 Notes...

Page 18: ...ww balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 919510 726 E 01 128382 Edition E19 Replaces Edition L14 Subjec...

Reviews: