Balluff BNI DNT-104-000-Z004 Short Manual Download Page 3

www.balluff.com

Balluff Network Interface / DeviceNet Fieldbus Distributor

Notes to the User

This Guide describes the Balluff DeviceNet Fieldbus Module BNI DNT-..., which enables expan-
ded communication down to the lowest level so as to provide improved process optimizing and 
preventive maintenance.

Note

A detailed operating manual for the BNI DNT-... can be found on the Internet at 

www.balluff.com.

The Guide is organized so that the sections build on one another.
Section   : Basic safety information.
Section   : The main steps for installing the device.
Section   4: Technical data for the device.

The following typographical conventions are used in this Guide.

Enumerations are shown in list form with bullet points.

Entry 1,
Entry .

Action instructions are indicated by a preceding triangle. The result of an action is indicated by 
an arrow.

Action instruction 1.

Action result.

Action instruction .

Numbers:

Decimal numbers are shown without additional indicators (e.g. 1),
Hexadecimal numbers are shown with the additional indicator 

hex

 (e.g. 00

hex

).

Directory paths:

References to paths in which data are stored or are to be saved to are shown in small caps (e.g. 
P

roject

:\D

ata

 t

yPes

\U

ser

 D

efineD

).

Cross-references indicate where additional information on the topic can be found 

(see"Technical 

data" on page 1)

.

Caution!

This symbol indicates a security notice which most be observed.

Note, tip

This symbol indicates general notes.

BCD

Binary coded switch

BNI

Balluff Network Interface

EMC

Electromagnetic Compatibility

DNT

DeviceNet

DR

Data rate

FE

Function ground

NA

Node Adress



1.1  About this guide

1.2  Structure of the 

guide

1.3  Typographical 

conventions

Enumerations

Actions

Syntax

Cross-references

1.4  Symbols

1.5  Abbreviations

1

Summary of Contents for BNI DNT-104-000-Z004

Page 1: ...BNI DNT 104 000 Z004 BNI DNT 202 000 Z005 BNI DNT 302 000 Z005 BNI DNT 305 000 Z005 Short Guide English...

Page 2: ...ons 3 Safety 4 2 1 Intended use 4 2 2 General safety notes 4 2 3 Meaning of the warnings 4 Getting Started 5 3 1 Connection overview 5 3 2 Mechanical connection 8 3 3 Electrical connection 9 3 4 Bus c...

Page 3: ...by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Numbers Decimal numbers are shown without additional indicators e g 123...

Page 4: ...st be powered only using an approved power supply see Technical data on page 12 Only approved cables may be used Operation and testing The operator is responsible for observing local prevailing safety...

Page 5: ...Fig 1 Connection overview BNI DNT 104 000 Z004 1 Mounting hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard I Port 4 7 Standard I Port 5 8 Standard I Port 6 9 Standard I...

Page 6: ...202 000 Z005 1 Mounting hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard O Port 4 7 Standard O Port 5 8 Standard O Port 6 9 Standard O Port 7 10 Standard O Port 3 11 S...

Page 7: ...302 000 Z005 1 Mounting hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard I O Port 4 7 Standard I O Port 5 8 Standard I O Port 6 9 Standard I O Port 7 10 Standard I O P...

Page 8: ...ing hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard I Port 2 7 Standard I Port 3 8 Standard O Port 2 9 Standard O Port 3 10 Standard O Port 1 11 Standard O Port 0 12 S...

Page 9: ...Provide sensor bus power and actuator power from separate power sources if possible Total current 9 A The total current of all modules may not exceed 9 A even when daisy chaining the actuator supply B...

Page 10: ...d with cover caps to ensure IP 67 protection rating The baud rate and DeviceNet address are set directly on the BNI DNT using BCD switches The following baud rates 1 are available Switch position 0 12...

Page 11: ...12 A coded freely configurable female Input Output Combined Inputs Outputs PIN Function Function Input Function Output 1 24 V n c 24V n c 2 Signal 2 n c Signal 2 24V 3 0 V 0 V 0 V 0V 4 Signal 1 24 V S...

Page 12: ...lated Fieldbus DeviceNet 7 8 5 pin male and female Supply voltage 7 8 4 pin male I O ports M12 A coded 8x female Enclosure rating IP67 only when plugged in and threaded in Weight approx 580 g Operatin...

Page 13: ...e BNI DNT 104 000 004 This indicator is not present on the BNI DNT 104 000 004 and BNI DNT 202 000 Z005 Each M12 port I O interface is assigned two 2 color LEDs which indicate the configuration or ope...

Page 14: ...rd inputs 8 standard outputs 2 A Variants 000 no variant Mechanical configuration Z004 Zinc die cast housing Material 1 Balluff housing version Bus connection 7 8 internal thread and 7 8 external thre...

Page 15: ...Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 IN Word 0 I 15 I 14 I 13 I 12 I 11 I 10 I 9 I 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 I 0 Word 1 S 15 S 14 S 13 S 12 S 11 S 10 S 9 S 8 S 7 S 6 S 5 S 4...

Page 16: ...Balluff GmbH Schurwaldstra e 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 857916 E Edition 0708 Subject to modification www balluff com www balluff com...