Installation and connection (continued)
Example procedure for installing the magnetic tape using
the installation aid:
1.
Fasten the installation aid (accessory) to the left or right
side of the sensor head using screws (see Fig. 4-2).
2.
Thoroughly remove any oil, grease, dust, etc. (use
acetone or similar) from the mounting surface of the
tape and allow to dry completely.
3.
Align the magnetic tape corresponding to the print (see
4.
Position the sensor head on the back end of the
magnetic tape to be applied (beginning of the
measuring range).
5.
Remove the protective film on the rear end of the
magnetic tape and lightly apply the magnetic tape.
6.
Remove another section of the protective film.
7.
Move the sensor head forward a bit while applying the
magnetic tape flush with the installation aid (see
Fig. 4-2).
8.
Lightly press the magnetic tape down by hand behind
the sensor head.
9.
Optional: Fasten the magnetic tape ends.
10.
Optionally: To protect the magnetic tape from
mechanical and chemical influences, affix the stainless
steel cover strip (for details, see the magnetic tape
instructions). Carefully clean the magnetic tape
beforehand (dry cloth, acetone, turpentine, mild plastic
cleaner,
no
benzine) to ensure the secure adhesion of
the cover strip.
11.
Remove the installation aid.
Installation aid
Sensor head
Machine part
Magnetic tape
Mounting surface
Apply the magnetic tape flush
with the installation aid
Fig. 4-2: Fastening installation aid BAM TO-ML-006-S1G (order
code BAM0256)
(left- or right-sided fastening is possible, figure shows
right-sided fastening)
4.2
Assembling the magnetic tape
The magnetic tape is not included in the scope
of delivery and must be ordered separately by
the roll or precut to specific lengths (see
For a complete technical description and
assembly instructions for magnetic tapes,
please see the magnetic tape user’s guide on
the Internet at
www.balluff.com
.
Ideally, the system should include a groove or a stop edge
for the magnetic tape that clearly defines its lateral
position. If there is no stop edge, the magnetic tape can be
installed in the center below the sensor head using the
installation aid (BAM TO-ML-006-S1G, page 23).
NOTICE
Damage to the magnetic tape
Hard tools may cause damage to the magnetic surface
of the magnetic tape. Even damage that appears slight
(e.g. scratches, dents) can affect the function and
linearity.
►
Do not use hard tools to install the magnetic tape!
►
Replace damaged magnetic tapes!
For safe operation, the magnetic tape must
protrude ≥ 5 mm from the bottom of the
housing in both end positions.
BML SL1-ALZ1- _ _ ZZ -ABA _ - S284/KA _ _
Absolute magnetic encoder system
english
Summary of Contents for BML SL1-ALZ1 ZZ-ABA S284/KA Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BML SL1 ALZ1 _ _ZZ ABA_ S284 KA_ _...
Page 4: ...www balluff com...
Page 30: ......
Page 31: ...english User s Guide BML SL1 ALZ1 _ _ZZ ABA_ S284 KA_ _...
Page 32: ...www balluff com...
Page 58: ......
Page 59: ...fran ais Notice d utilisation BML SL1 ALZ1 _ _ZZ ABA_ S284 KA_ _...
Page 60: ...www balluff com...
Page 86: ......
Page 87: ...italiano Manuale d uso BML SL1 ALZ1 _ _ZZ ABA_ S284 KA_ _...
Page 88: ...www balluff com...
Page 114: ......
Page 115: ...espa ol Manual de instrucciones BML SL1 ALZ1 _ _ZZ ABA_ S284 KA_ _...
Page 116: ...www balluff com...
Page 142: ......
Page 143: ......