Validity
This guide describes the construction, function and
installation options for the BML absolute magnetically
coded position measuring system. It applies to the
following models (see part numbering on page 46):
–
BML SL1-ALZ0-U1ZZ - _ U1L- S284/S4/KA _ _
–
BML SL1-ALZ1-UE/MZZ- _ U1L -S284/S4/KA _ _
–
BML SL1-ALZ1- _ _ ZZ -ABA _ - S284/KA _ _
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the linear
head.
Additional information about the interfaces can
be found in the document
Interfaces for BML
Magnetic Encoder
1.2
Symbols and conventions
Individual
instructions
are indicated by a preceding
triangle.
►
Instruction 1
Action sequences
are numbered consecutively:
1.
Instruction 1
2.
Instruction 2
Numbers
unless otherwise indicated are decimals (e.g.
23). Hexadecimal numbers are represented with preceding
0x (e.g. 0x12AB).
Note, tip
This symbol indicates general notes.
1.3
Scope of delivery
– Sensor head BML SL1
– Condensed guide
Magnetic tapes are available in various models
and must be ordered separately (see
1.4
Approvals and markings
UL approval
File no.
E227256
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
The transducer meets the requirements of the following
product standard:
– EN 61326-2-3 (noise immunity and emission)
Emission tests:
– RF emission
EN 55011
Noise immunity tests:
– Static electricity (ESD)
EN 61000-4-2
Severity level 4
– Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
– Electrical fast transients (burst)
EN 61000-4-4
Severity level 3
– Surge EN 61000-4-5
Severity level 2
– Conducted interference induced by
high-frequency fields EN 61000-4-6 Severity level 3
– Magnetic fields EN 61000-4-8
Severity level 5
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
1.5
Abbreviations
1Vpp
Incremental sin/cos interface
BML
Balluff magnetic linear head system
CRC
Cyclic Redundancy Check
IODD
IO Device Description
MDC
Measurement Data Channel
PD
Process Data
PDV
Process Data Variable
SIO
Standard Input Output
SSC
Switching Signal Channel
1
Notes to the user
BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
english
Summary of Contents for BML SL1-ALZ-ZZ Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 4: ...www balluff com...
Page 53: ...english User s Guide BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 54: ...www balluff com...
Page 103: ...fran ais Notice d utilisation BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 104: ...www balluff com...
Page 153: ...italiano Manuale d uso BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 154: ...www balluff com...
Page 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 204: ...www balluff com...
Page 253: ......