Process Data Information and Configuration
Process Data Profile
selection
0x0051
(81)
0
R/W
1 byte
UINT8(ENUM)
Yes
Standard: 0x01
CCM: 0x02
Process Data Input
Descriptor
0x000E
(14)
0
R
3 × PD
length
UINT8[]
n/a
–
Process Data Output
Descriptor
0x000F
(15)
0
R
3 × PD
length
UINT8[]
n/a
–
Last Valid Process
Data Inputs
0x0028
(40)
0
R
Standard:
32 bytes
CCM:
17 bytes
–
n/a
–
Last Valid Process
Data Outputs
0x0029
(41)
0
R
Standard:
32 bytes
CCM:
16 bytes
–
n/a
–
Profile Characteristic
Profile Characteristic
0x000D
(13)
0
R
6 bytes
UINT16[]
n/a
–
Tab. 3-3: ISDU – Identification Data
3.5
System Commands
Command Value
Device Action
0x80 (128)
Device Reset
– Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values (see chapter 7.3 on page 56).
0x81 (129)
Application Reset
0x82 (130)
Reset Factory Settings
0xA5 (165)
Maintenance Reset
0xA7 (167)
Statistics Reset
– Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg
– Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics operation completely.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving average calculation.
0xAF (175)
Start Device Discovery
0xC0 (192)
Set Reference Orientation
– Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.