8
english
3.1
Overview of the included Functions
3.1.1 Primary Functions
–
–
–
–
–
3.1.2 Secondary Functions
–
–
–
–
Voltage and Current Monitoring
–
–
–
Inclination and Installation Aid
–
–
–
3.1.3 System functions
–
Device Status and Detailed Device Status
see
–
–
–
–
–
–
Process Data Info and Configuration
–
–
3
Overview of IO-Link Data and Functions
3.2
Device Variants
The following variants are available:
– Standard
– Comprehensive Condition Monitoring (CCM)
The variants differ only in their process data profiles. The
functions remain unchanged.
Variant 1
(Standard)
Variant 2
(CCM)
Device ID
0x060301
0x060238
Baud rate
COM3 (230.4 kbits/s)
Qty. of process data - input
data
32 Byte
17 Byte
Qty. of process data -
output data
32 Byte
16 bytes
IO-Link protocol version
1.12
Minimum cycle time of
device
3.7 ms
2.6 ms
Tab. 3-1: Device Variants
3.3
Process Data Profiles
3.3.1 Variant 1 (Standard)
PDInput
32 bytes (0…31) RFID process data
PDOutput
32 bytes (0…31) RFID process data
3.3.2 Variant 2 (CCM)
PDInput
16 bytes (0…15) RFID process data
1 byte (16) CCM
bytes16
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
System Err
or
Signal Quality
Status
Reserved
Temperatur
e
Status Customer
Limits
Inclination Alarm
Status
V
ibration Alarm
Status
Humidity Status
Tab. 3-2: PD Input process data profile, byte 16
PD Output
16 bytes (0…15) RFID process data
BIS U-4A7-082- _1C-07-S4
Industrial RFID system
Summary of Contents for BIS U-4A7-082-01C-07-S4
Page 2: ...www balluff com...
Page 4: ...www balluff com...
Page 70: ......