56
Write 18 bytes starting at data carrier address 20
Command from controller
BIS M-4_ _-045-... reaction
1. Process subaddresses in the order
shown:
2. Process input buffer:
01
hex
Command designator 02
hex
00
hex
/09
hex
Set AA
02
hex
Start address 14
hex
03
hex
Start address 00
hex
04
hex
No. of bytes 12
hex
05
hex
No. of bytes 00
hex
00
hex
/09
hex
Set AV
3. Process subaddresses:
4. Copy received data, process subaddres-
ses of the input buffer:
01
hex...
08
hex
Enter the first 8 bytes of data
00
hex
/09
hex
Invert TO
00
hex...
07
hex
Invert TI
5. Process subaddresses:
6. Copy received data, process subaddres-
ses of the input buffer:
01
hex...
08
hex
Enter the second 8 bytes of
data
00
hex
/09
hex
Invert TO
00
hex...
09
hex
Invert TI
7. Process subaddresses:
8. Copy received data, process subaddres-
ses of the input buffer:
01
hex...
02
hex
Enter the remaining 2 bytes of
data
00
hex
/09
hex
Set AE
00
hex...
09
hex
Invert TI
9. Process subaddresses:
10. Process subaddresses:
00
hex
/09
hex
Delete AV
00
hex
/09
hex
Delete AA and AE
Example 9.
(for 10 bytes of
process data)
9
Device Function
BIS M-4 _ _ IO-Link Device
Read/Write Device
Summary of Contents for BIS M-4 045 0 07-S4 Series
Page 2: ...www balluff com...
Page 4: ...www balluff com www balluff com...
Page 67: ...www balluff com 65 BIS M 4_ _ IO Link Device Schreib Leseger t...
Page 70: ...www balluff com www balluff com...
Page 133: ...www balluff com 65 BIS M 4_ _ IO Link Device Read Write Device...
Page 135: ...BIS M 4_ _ 045 _0_ 07 S4 BIS M 4_ _ 072 _0_ 07 S4...
Page 136: ...www balluff com www balluff com...
Page 141: ...www balluff com 7 1 BIS CRC DPP EMC LSB MSB PC SIO IO SPDU PLC TCP 1 6 1 7 BIS M 4_ _ IO Link...
Page 142: ...8 BIS M 4xx_ _ BIS M EMC A IO Link BIS M 4_ _ 24 A 2 1 2 2 2 3 2 BIS M 4_ _ IO Link...
Page 152: ...18 3 IO Link M12 A 1 24 V 2 3 GND 4 C Q 2 2 2 IO Link IO Link RC 3 2 BIS M 4_ _ IO Link...
Page 199: ...www balluff com 65 BIS M 4_ _ IO Link...
Page 201: ......