Appendix, ASCII Table

Deci-

mal

Hex

Control

Code

ASCII

Deci-

mal

Hex

Control

Code

ASCII

Deci-

mal

Hex ASCII

Deci-

mal

Hex ASCII

Deci-

mal

Hex ASCII

Deci-

mal

Hex ASCII

0

00

Ctrl @

NUL

22

16

Ctrl V

SYN

44

2C

,

65

41

A

86

56

V

107

6B

k

1

01

Ctrl A

SOH

23

17

Ctrl W

ETB

45

2D

-

66

42

B

87

57

W

108

6C

l

2

02

Ctrl B

STX

24

18

Ctrl X

CAN

46

2E

.

67

43

C

88

58

X

109

6D

m

3

03

Ctrl C

ETX

25

19

Ctrl Y

EM

47

2F

/

68

44

D

89

59

Y

110

6E

n

4

04

Ctrl D

EOT

26

1A

Ctrl Z

SUB

48

30

0

69

45

E

90

5A

Z

111

6F

o

5

05

Ctrl E

ENQ

27

1B

Ctrl [

ESC

49

31

1

70

46

F

91

5B

[

112

70

p

6

06

Ctrl F

ACK

28

1C

Ctrl \

FS

50

32

2

71

47

G

92

5C

\

113

71

q

7

07

Ctrl G

BEL

29

1D

Ctrl ]

GS

51

33

3

72

48

H

93

5D

]

114

72

r

8

08

Ctrl H

BS

30

1E

Ctrl ^

RS

52

34

4

73

49

I

94

5E

^

115

73

s

9

09

Ctrl I

HT

31

1F

Ctrl _

US

53

35

5

74

4A

J

95

5F

_

116

74

t

10

0A

Ctrl J

LF

32

20

SP

54

36

6

75

4B

K

96

60

`

117

75

u

11

0B

Ctrl K

VT

33

21

!

55

37

7

76

4C

L

97

61

a

118

76

v

12

0C

Ctrl L

FF

34

22

"

56

38

8

77

4D

M

98

62

b

119

77

w

13

0D

Ctrl M

CR

35

23

#

57

39

9

78

4E

N

99

63

c

120

78

x

14

0E

Ctrl N

SO

36

24

$

58

3A

:

79

4F

O

100

64

d

121

79

y

15

0F

Ctrl O

SI

37

25

%

59

3B

;

80

50

P

101

65

e

122

7A

z

16

10

Ctrl P

DLE

38

26

&

60

3C

<

81

51

Q

102

66

f

123

7B

{

17

11

Ctrl Q

DC1

39

27

'

61

3D

=

82

52

R

103

67

g

124

7C

|

18

12

Ctrl R

DC2

40

28

(

62

3E

>

83

53

S

104

68

h

125

7D

}

19

13

Ctrl S

DC3

41

29

)

63

3F

?

84

54

T

105

69

i

126

7E

~

20

14

Ctrl T

DC4

42

2A

*

64

40

@

85

55

U

106

6A

j

127

7F

DEL

21

15

Ctrl U

NAK

43

2B

+

BIS L-405-03_-00_-05-MU_834487_E_0709.p65

Summary of Contents for BIS L-405-033-00*-05-MU

Page 1: ...0_ 05 MU Manual Deutsch bitte wenden BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 2 No 834 487 D E Edition 0709 Specifications subject to change Replaces edition 0605 Balluff GmbH Schurwaldstrasse 9 7376...

Page 2: ...laims When installing the processor follow exactly the connection diagrams provided later in this document Take special care when connecting the processor to external controllers espe cially with resp...

Page 3: ...unit It does not require line fed power and receives its energy from the integrated read head in the BIS L 405 identification system The read head continuously sends a carrier signal which supplies t...

Page 4: ...data carrier is indicated by the TP signal The first data value is not output until the ADR input signal changes Each time ADR changes the value of the next address is given to the data outputs As an...

Page 5: ...sponse to address change 15 ms t3 STR acknowledges ReStart finished 7 ms BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 10 english 10 Application BIS L 405 Processor Restart with no data carrier present If...

Page 6: ...405 03_ 00_ 05 MU_834487_E_0709 p65 12 english 12 Application BIS L 405 Processor Wiring up to 8 BIS L 405 processors in parallel The data lines from up to 8 BIS L 405 processor can be connected in p...

Page 7: ...used with the BIS L 405 033 processor because there is no CRC 16 check BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 14 english 14 tx t1 t1 t1 t1 t1 t2 t2 t2 t2 t2 CRC data check with BIS L 405 037 CRC er...

Page 8: ...account the conveyor speed Distance between the data carriers in m 0 4 x conveyor speed in m s 0 25 m Example Conveyor speed 1 m s Distance 0 4 x 1 m s 0 25 m 0 65 m This is an approximation for the w...

Page 9: ...t read distance mm Speed m s BIS L 100 05 15 0 45 BIS L 101 05 20 0 5 BIS L 102 05 27 5 0 72 BIS L 103 05 10 0 36 BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 18 english 18 BIS L 405 002 Installation Ins...

Page 10: ...n BIS L 405 004 Specifications by data carrier BIS L 405 037 004 Specifications by data carrier BIS L 405 033 004 BIS L 405 004 Installation Specifications by data carrier installed in clear zone For...

Page 11: ...GRAY ROSE ADR RED BLUE SHIELDING SHIELD n c YELLOW BROWN BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 22 english 22 BIS L 405 Installation When installing BIS L 405 and BIS L 503 remove the PG fitting In...

Page 12: ...on Rotating the read head Read head modules are not interchangeable Active surface positions Read head base Screw Active surface Set screw BIS L405 module BIS L 503 mounting base Read head module BIS...

Page 13: ...EMC Laboratory which is accredited by the DATech for Testing Electromagnetic Compatibility we have verified that Balluff products meet the EMC re quirements of the following Generic Standards EN 6100...

Page 14: ...29 1D Ctrl GS 51 33 3 72 48 H 93 5D 114 72 r 8 08 Ctrl H BS 30 1E Ctrl RS 52 34 4 73 49 I 94 5E 115 73 s 9 09 Ctrl I HT 31 1F Ctrl _ US 53 35 5 74 4A J 95 5F _ 116 74 t 10 0A Ctrl J LF 32 20 SP 54 36...

Reviews: