19
19
english
15
Sensing
surface
Read/Write Head
BIS C-305-_ _
Dimensions
Standard:
Length _ _
01 =
1 m
05 =
5 m
10 = 10 m
Distances and
Velocities between
Read/Write Head
and matching
Data Carrier
Matching Data Carrier
Static Mode (V = 0)
Dynamic Mode (V > 0)
Distance [m m]
Offset [m m] at a distance [m m] of
Distance
[mm]
Vmax. [m/min]
1)
Read
Write
0.7
1
3
5
7
10
Read
Write
for
flush
moun-
ting
in
steel
BIS C-100-05/A
2)
0 to 4
0 to 4
± 3
± 2
1
8
BIS C-103-_ _/A
2)
0 to 5
0 to 5
± 4
± 3
1
10
BIS C-105-_ _/A
2)
0 to 5
0 to 5
± 4
± 3
1
10
BIS C-117-05/A
2)
1 to 8
1 to 8
± 5
± 4
± 3
1 to 5
12 to 7
7 to 4
BIS C-121-04/L
0 to 2
0 to 2
± 2
1
6
BIS C-121-04/L-SA1
0 to 1.2
0 to 1.2
± 2
BIS C-122-04/L
0 to 2.5
0 to 2.5
± 3
± 2
1
8
non-
flush
BIS C-108-_ _/L
0 to 6
0 to 6
± 8
± 7
± 5
1 to 5
20 to 12
12 to 7
BIS C-108-_ _/L-SA2
0 to 6
0 to 6
± 8
± 7
± 5
1 to 5
20 to 12
12 to 7
BIS C-117-05/L
0 to 7
0 to 7
± 8.5
± 7.5
± 6
± 4
1 to 5
21 to 16
12 to 9
BIS C-117-05/A
0 to 10
0 to 10
± 6
± 6
± 6
± 5
± 3
2 to 8
16 to 13
9 to 7
BIS C-128-05/L
0 to 6
0 to 6
± 8
± 7
± 5
1 to 5
20 to 12
12 to 7
BIS C-130-05/L
0 to 7
0 to 7
± 5
± 5
± 4
± 2
1 to 6
14 to 11
11 to 6
BIS C-130-05/L-SA1
0 to 7
0 to 7
± 5
± 5
± 4
± 2
1 to 6
14 to 11
11 to 6
BIS C-130-05/L-SA2
0 to 6.2
0 to 6.2
± 5
± 5
± 4
1 to 5
14 to 11
11 to 6
1)
The indicated relative speeds assume a read or write of the first 4 bytes of the data carrier (bytes 0...3).
2)
This data carrier is appropriate for installation in aluminum. Dynamic operation not permitted!
C3-slk_716464_E_1110.p65
20
english
20
20
35
[
35
Ø
m
50
60
42
24
Ø
14.5
M12×1
24
M18×1
L = _ _
Sensing
surface
Read/Write Head
BIS C-319-_ _
Distances and
Velocities between
Read/Write Head
and matching
Data Carrier
Clear zone in metal
Matching Data Carrier
Static Mode (V = 0)
Dynamic Mode (V > 0)
Distance [mm]
Offset [mm] at a distance [mm] of
Distance
[mm]
Vmax. [m/min]
1)
Read
Write
1
3
5
7
10
Read
Write
non-
flush
BIS C-108-_ _/L
0 to 14
0 to 14
± 12
± 12
± 11
± 11
± 9
0 to 10
26 to 20
17 to 13
BIS C-117-05/L
0 to 15
0 to 15
± 13
± 12
± 12
± 11
± 10
0 to 10
31 to 22
18 to 15
BIS C-130-05/L
0 to 13
0 to 13
± 9
± 9
± 9
± 8.5 ± 7.5
0 to 10
23 to 19
13 to 11
BIS C-130-05/L-SA1
0 to 13
0 to 13
± 9
± 9
± 9
± 8.5 ± 7.5
0 to 10
23 to 19
13 to 11
BIS C-130-05/L-SA2
0 to 12
0 to 12
± 9
± 9
± 9
± 8
± 6
0 to 9
23 to 19
13 to 11
BIS C-191-_ _/L
0 to 11
0 to 11
± 9
± 9
± 9
± 8
0 to 8
22 to 20
13 to 11
Dimensions
Standard:
Length _ _
01 =
1 m
05 =
5 m
10 = 10 m
1)