background image

Balluff IO-Link System 

BIC 1B0-ITA50-Q40KFU-SM4A4A (Base) 

BIC 1B0-IT005-Q40KFU-SM4A4A (Base) 

BIC 2B0-ITA50-Q40KFU-SM4A5A (Remote) 

 

 www.balluff.com 

   

 

 

1  Safety 

1.1.  Installation and 

startup 

 

 

Attention! 

Installation and startup are to be performed only by trained specialists. Qualified 

personnel are persons who are familiar with the installation and operation of the 

product, and who fulfills the qualifications required for this activity. Any damage 

resulting from unauthorized manipulation or improper use voids the 

manufacturer's guarantee and warranty. The Operator is responsible for 

ensuring that applicable of safety and accident prevention regulations are 

complied with. 

 

1.2.  General safety 

instructions 

  Commissioning and inspection 

The operating company shall be responsible for observance of locally applicable safety 

instructions. 

Before commissioning, carefully read the operating manual. 

The system must not be used in applications in which the safety of persons is dependent on 

the function of the device. 

Authorized Personnel 

Installation and commissioning may only be performed by trained specialist personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

  Unauthorized tampering 

  Improper use 

  Use, installation or handling contrary to the instructions provided in this operating 

manual 

Obligations of the Operating Company 

The device is a piece of equipment from EMC Class A. Such equipment may generate RF 

noise. The operator must take appropriate precautionary measures. The device may only be 

used with an approved power supply. Only approved cables may be used. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 

taken out of operation and protected against unauthorized use. 

 

Hazardous 

voltage 

 

 

Attention! 

Disconnect all power before servicing equipment. 

 

Intended use 

 

 

Attention! 

Inductive coupling systems (BIC) are devices for contactless energy and 

signal transmission in industrial environments. 

 

Prohibited is the use: 

  in environment with explosive atmosphere. 

  in application where the safety of persons or machines depends on the 

transmitted signals. (Safety circuits) 

 

1.3.  Safety 

instructions 

 

 

Caution! 

Risk of burning on hot surfaces! The sensing surface heats up under normal 

operating conditions. 

Keep hands and objects away from the active surface. 

Metallic objects should not reach the area between the sensing surfaces 

of the base and remote units. 

Fire hazard! 

 

1.4.  Differing views 

  Product views and images in this manual may differ from the product described. They are 

intended to serve only as illustrations. 

 

Summary of Contents for BIC 1B0-ITA50-Q40KFU-SM4A4A

Page 1: ...BIC 1B0 ITA50 Q40KFU SM4A4A BIC 1B0 IT005 Q40KFU SM4A4A BIC 2B0 ITA50 Q40KFU SM4A5A User s Guide...

Page 2: ...ng the holder 7 4 Energy Transfer 8 4 1 Derating 8 Derating curve output power of the remote at 24V 5 8 Note 8 4 2 Reduction of the power emitted at the base when the remote is disconnected 8 Technica...

Page 3: ...Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this operating manual Obligations of the Operating Company The device is a piece of equipment...

Page 4: ...e reference values of the EU council recommendation 1999 519 EC EN 62311 2008 and has to be ensuring as value for safety of human exposure to electromagnetic fields It s possible that for people with...

Page 5: ...data see previous picture from the IO Link master to the BIC system component remote In this way the IO Link functionality of the IO Link port on the master is made available without contact on the r...

Page 6: ...Device damage due to induction effects Metallic objects on and in front of the coil cap will be heated The active area is characterized by the cross hairs on the body See figure chapter 3 1 The compo...

Page 7: ...BIC 2B0 ITA50 Q40KFU SM4A5A Remote www balluff com 6 3 Installation 3 3 Distances offset Permitted distances offset of the axes Type A mm B mm BIC 1B0 ITA50 Q40KFU SM4A4A 5 5 BIC 2B0 ITA50 Q40KFU SM4...

Page 8: ...nsert is rotated step 7 subsequent reassembly is performed in reverse order Removing the holder 1 Loosen the grub screw 2 Pull off the BIC holder 3 Loosen the two countersunk screws 4 Remove the BIC b...

Page 9: ...tput power of the remote at 24V 5 Note The measurement on which the derating curve is based was carried out without axis and angular offset The value ranges of the derating curve are to be interpreted...

Page 10: ...from the IO Link port on the master to the IO Link device 5 2 Connection time The time needed to establish the connection of base and remote is affected by many different variables Start up speed and...

Page 11: ...ply voltage OK Green inverted flashing IO Link connection OK LED 2 Yellow flashing No Remote found Yellow static Remote found Red flashing Undervoltage Mechanical data Housing material Black plastic P...

Page 12: ...Electrical data Supply voltage 24 V DC 10 by EN 61131 2 Current consumption 1 4 A Standby current 200 mA Overload protection Yes Ripple 1 Pin Assignment Power M12 4 pin socket PIN Signal 1 24 V 2 Tran...

Page 13: ...ed flashing IO Link connection OK LED 2 Yellow on Pin 2 high Yellow off Pin 2 low Mechanical data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed...

Page 14: ...www balluff com 13 6 Technical data Pin Assignment Power M12 5 pin connector PIN Signal 1 24 V 2 Transparent output 3 GND 0V 4 C Q IO Link 5 NC...

Page 15: ...IT005 Q40KFU SM4A4A Base BIC 2B0 ITA50 Q40KFU SM4A5A Remote www balluff com 14 7 Order information Ordering information Product ordering code Ordering code BIC 1B0 ITA50 Q40KFU SM4A4A BIC0070 BIC 1B0...

Page 16: ...ww balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 898544 E 726 06 127436 Edition K18 Replaces Edition K14 Subjec...

Reviews: