![Balluff BFS 33M-GSI-F01-S75 Interface Description Download Page 19](http://html1.mh-extra.com/html/balluff/bfs-33m-gsi-f01-s75/bfs-33m-gsi-f01-s75_interface-description_3707484019.webp)
Photoelectric Sensors
True-Color-Sensor BFS 33M with IO-Link
Page 19 / 24
8.4. System command
Index
Data
format
Access
Value range
Remarks
0x0002
(2)
System
Command
UINT8
W
0x80 = Device reset
Warm start
sensor
0x82 = Restore factory setting
Factory settings
all parameter
0xA3 = Compensate
Environment
Scattered light
compensation
0xA4 = Calibration
Perform sensor
calibration
Table 4 : System command
Explanations for Table 4
Value 0x80 (Device reset)
This function enables a warm start of the sensor.
Value 0x82 (Restore factory setting):
This system command resets all of the sensor's parameters to their factory setting.
This process may take several seconds (until fully executed on the sensor).