background image

 

BF-IDU03

 

RFID-Reader 
 

Connecting the Device 

 
The device has to be connected to one of the head connectors "H1" .. "H4" of a Balluff BIS V 
control unit via standard 4-wire cable with M12 industry connectors. The control unit delivers 
power supply and controls the device over this connection.  
 

Make an additional ground connection to the Functional Ground terminal (Symbo

) either 

directly or using an RC combination to ground. 

  

        

 

The control unit itself needs to be connected to a power supply and the customer's PLC unit. 
See the BIS V manual for details. 

 
Mounting 

 
Before operating, the device has to be fixed mounted with at least 2 screws of M4 or M5 size in 
mounting holes at back side (see image).  
The BF-IDU03 device may be mounted in any direction, the operating direction of the integrated 
antenna is towards the front containing the "BIS VU Identification Systems" label. 
Optional mounting plates are available for installing the device. 
 

                                                           

 

The antennas of the identification system BIS U transmit ultra-high frequency electromagnetic 
waves. People should not remain within close range of the UHF antenna for long periods 
(several hours). When selecting the installation position for the BF-IDU03 device, make sure 
that the minimum distance between the UHF antenna and the workplace is 25 cm. 

 

 

BF-IDU03 

BIS V-6xxx 

Reviews: