background image

 Installation Guide - BCS Q40BBAA-GPCFHC… 

Inte nde d use  

Smart

Level

 sensors are suitable for fill level detection.  

 

1) active area  2) yellow indication -> switching state  3) green indication -> 
power  4) potentiometer 

 
Flawless function in accordance with the specification as in the technical data is 
ensured only when using original BALLUFF accessories, and use of any other 
components will void the warranty. 

Modifications to the sensor or non-approved use are not permitted and will 
result in loss of warranty and void any liability claims against the manufacturer. 

 

Safety  in stru ct io n  

 

These sensors must not be used in application in which the safety of 
persons is dependent on the function of the device (not a safety 
component acc. to EU Machinery Directive). 

This mounting guide is intended for qualified persons only. Read this guide 
carefully before installing or commissioning this device. 

The operator is responsible for ensuring that local safety regulations are 
observed. In particular, the operator must take measures to ensure that a 
defect in the device will not result in hazards to persons or equipment. 

If defects or non-clearable faults in the device occur, take it out of service and 
secure against unauthorized use. 

 

Electr i ca l c o nne ct io n  

Connection cable types: 

 

Connection M8 connector PNP NO: 

 Connection M8 connector PNP NC: 

 

Connection M8 connector NPN NO:  

Connection M8 connector NPN NC: 

 

P in   c o n f ig u r a t io n   M 8   c o n n e c t o r :  

 

 

Wiri ng  

Don't lay the connection cable direct behind the sensor ring-shaped. Instead 
cut the connection cable to the needed length.   

 

 

Ad jus tmen t  

Smart

Level s

ensors have already a factory adjustment which is suitable for the 

most standard applications, without a user adjustment. 

With this adjustment the sensor is able to detect reliable liquid and conductive  
medias through container walls made of glass and plastic.  The factory  
adjustment penetrates container walls made of glass or plastic, even at 
thicknesses up to 6mm. 

Smart

Level s

ensors compensates for condensation, 

foaming, filming or material build-up.   

If necessary, in exceptional cases the factory adjustment can be changed with 
potentiometer (4) and the enclosed srew driver. 

 

F u ll  le v e l  a d j u s tm e n t  in   e x e p t io n a l  c a s e s :  

Fill level should be approximately 50% from the active area. If the sensor 
already detect the fill level , turn the potentiometer counterclockwise until the 
sensor output turn off. 

Now turn the potentiometer slowly clockwise until the sensor output turn on 
again.  Then turn addional a half turn clockwise and the sensor is adjusted.  

 

E m p ty   a d j u s tm e n t  in   e x e p tio n a l  c a s e s :  

If the sensor already detect the empty container, turn the potentiometer 
counterclockwise until the sensor output turn off.  

Now turn the potentiometer slowly clockwise until the sensor output turn on 
again. Then turn 3 times counterclockwise and the sensor is adjusted. 

 

Moun ti ng  

 

 

 

 

 

Furt her  inf ormat i ons  

More information (datasheet, construction data, accessories) can be found 
with the order code on the internet at 

www.balluff.com 

 

 

D

o

k.

-N

r.

 9

1

9

5

8

2

-7

7

7

 D

E

 0

1

 0

0

0

0

0

0

  C

1

5

  :

 Ä

n

d

e

ru

n

ge

n

 v

o

rb

e

h

al

te

n

 E

rs

e

tz

A

u

sg

ab

e

 A

1

5

 

Balluff GmbH 

Schurwaldstrasse 9 

73765 Neuhausen a.d.F. 

Phone +49 (0) 71 58/1 73-0 

Fax +49 (0) 71 58/50 10 

[email protected] 

Reviews: