No. 931018 EN · D19; Subject to changes. Replaces I16.
Technical Data
Dimensions
84.1 × 107 × 124.5 mm
(BAM PC-OS-024-23K-1)
89.1 × 133 mm × 135.7 mm
(BAM PC-OS-024-50K-1)
Sensing surface
(plate)
23.5 mm × 43 mm
(BAM PC-OS-024-23K-1)
26 mm × 74.6 mm
(BAM PC-OS-024-50K-1)
Degree of
protection as per
IEC 60529
IP67
Application
weight (without
sensor)
650 g (BAM PC-OS-024-23K-1)
880 g (BAM PC-OS-024-50K-1)
Permissible
ambient
temperature
–5…+70 °C
Permissible
ambient
temperature for
cooling water
connection
–5…+160 °C (for water connection
8 °C, 2 l/min); not permitted in
explosion hazard areas
Accessories
Please order accessories separately.
Description
Type Code
Ordering Code
Water connection for 23K
BAM PC-OS-026-23K-1
BAM029K
Water connection for 50K
BAM PC-OS-026-50K-1
BAM029P
Air blow-off
BAM AN-AM-001-01-1
BAM029N
Protective cover for housing 23K
BAM PC-OS-024-23K-G/RK
BAM029E
Protective cover for housing 50K
BAM PC-OS-024-50K-G/RK
BAM029H
Cable 5 m
BCC S415-0000-1A-003-PX0434-050
BCC0EZ9
Cable 10 m
BCC S415-0000-1A-003-PX0434-100
BCC0EZA
DANGER
Ignition hazard
The water and air connection lines must not cause
ignition hazard. This can lead to device damage and
serious injuries or death.
►
Use the water connection parts and air curtain only
according to
Summary of Contents for BAM PC-OS-024-23K-1
Page 1: ...deutsch Betriebsanleitung english User s Guide BAM PC OS 024 23K 1 BAM PC OS 024 50K 1 ...
Page 2: ...www balluff com ...
Page 4: ......
Page 9: ...BAM PC OS 024 23K 1 BAM PC OS 024 50K 1 Betriebsanleitung deutsch ...
Page 14: ......
Page 15: ...english BAM PC OS 024 23K 1 BAM PC OS 024 50K 1 User s Guide ...