26
5.REFRIGERANT SYSTEM DIAGRAM
MAX. REFRIGERANT PIPING LENGTH
Piping size O.D : mm
Length of connecting pipe : m
Modles
Refrigerant Piping
Max. Length : m
A
Gas
Liquid
Indoor unit
Outdoor unit
KFR-4801GWE
15
12.7
6.35
KF-5002GWE
15
12.7
6.35
MAX. HEIGHT DIFFERENCE
Indoor
unit
`
Refrigerant piping
Max. length
Max. Height
A
difference 7m
Outdoor unit
ADDITIONAL; REFRIGERANT CHARGE(R-22 : g)
Refrigerant piping length (one way)
Modles
Outdoor unit precharged
(up to 7m)
7m
10m
15m
KFR-4801GWE
1750
0
150
400
KF-5002GWE
1850
0
150
400
Canculation :Xg=50g/m * (A-7)m