OPERATING  INSTRUCTIONS

C  O  M  M  U  N  I  C  A  T  I  O  N  S

VIGIL EVAS BVRD2M

Operating Instructions

Manual name: BVRD2M

Issue: 2

ECN: 3082

Date of issue: August 2016

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for VIGIL EVAS BVRD2M

Page 1: ...RATING INSTRUCTIONS C O M M U N I C A T I O N S VIGIL EVAS BVRD2M Operating Instructions Manual name BVRD2M Issue 2 ECN 3082 Date of issue August 2016 www acornfiresecurity com www acornfiresecurity c...

Page 2: ...onment Classification E1 EMC EN55103 2 Environment Classification E5 Safety EN60065 Failure to use the equipment in the manner described in the product literature will invalidate the conformity A Decl...

Page 3: ...ations 5 Control Inputs Outputs 5 BVRD2S Slave Unit____________________________________6 Main Features 6 Rear Panel Connections 6 BVRD2SLT Light Slave Unit ____________________________6 BVRD2M CANBUS...

Page 4: ...tings General Description__________________ 23 Audio Output Settings General Description ________________ 24 DVA Message Settings General Description ________________ 25 Chimes General Description ___...

Page 5: ...tem or translate into any language any part of this manual without the prior permission of Baldwin Boxall Communications Limited In the interest of continual product development Baldwin Boxall Communi...

Page 6: ...aining This Manual contains Warnings Cautions and Notes Warnings describe potential threats to health or life e g Cautions describe potential threats to the equipment e g Notes are statements that are...

Page 7: ...re normally reserved for fire microphones and are configurable with an All Call processor bypass There are seven electronically balanced outputs each with 10 band parametric EQ and selectable audio de...

Page 8: ...ss to move right through available menus and options F Select navigation button Press to choose the currently selected option G Back navigation button Press to move back to the previous menu H Status...

Page 9: ...tions 2 x CAN BUS ports to enable additional Modules to be connected Refer to section 1 7 for details of these modules I RS485 Port Connections 2 x RS485 half duplex ports for communicating to control...

Page 10: ...z 630Hz 800Hz 1KHz 1 2KHz 1 6KHz 2KHz 2 5KHz Slope 3dB oct and 6dB oct Lift and Cut 12dB in 1dB steps High Filter Frequency 500Hz 630Hz 800Hz 1KHz 1 25KHz 1 6KHz 2KHz 2 5KHz 3 15KHz 4KHz 5KHz Lift and...

Page 11: ...eps Audio Delay Selectable from 0 to 1 second Control Inputs Fire Panel EM 1 x opto coupled sounder circuit All Evacuate input from fire detection system This input has an all call processor bypass Fi...

Page 12: ...tween master and slave units are through an internal data link 1 5 2 Rear Panel Connections Figure 1 3 BVRD2S Rear Panel All connections are made to the BVRD2S using RJ45 connectors The Bypass All Cal...

Page 13: ...ion 11 x amplifier surveillance 10 with auto change over 1 x RS485 half duplex ports for communicating to control microphones etc 1 7 3 BVRDFPI 24 x opto coupled inputs from fire detection systems 1 x...

Page 14: ...ting Instructions 8 BVRD2M issue 2 C O M M U N I C A T I O N S 1 8 SIMPLIFIED SCHEMATIC DIAGRAMS 1 8 1 BVRD2M BVRD2S Schematic Diagrams Figure 1 4 BVRD2M Schematic Diagram www acornfiresecurity com ww...

Page 15: ...VIGIL EVAS BVRD2M Operating Instructions BVRD2M issue 2 9 C O M M U N I C A T I O N S Figure 1 5 BVRD2S Schematic Diagram www acornfiresecurity com www acornfiresecurity com...

Page 16: ...NEXT MODULE SUPPLY RAILS BEL1 L S LINE MONITOR BVRDACO AMP OUTPUT VOLT SENSE AMPLIFIER CHANGEOVER RELAYS EARTH LEAK DETECTOR EOL VOLT DETECTOR AMP 2 OUTPUT AMP OUTPUT VOLT SENSE EARTH LEAK DETECTOR E...

Page 17: ...h Leakage is detected LF1 0 5V an Earth Fault will be announced and no further action is taken B If Open Circuit line is detected LF1 0 5V AF1 0V a Line O C Fault will be announced and no further acti...

Page 18: ...FROM PREVIOUS MODULE CAN BUS B TO NEXT MODULE SUPPLY RAILS FIRE PANEL INTERFACE BVRDFPI OPTO ISOLATOR OPTO ISOLATOR OPTO ISOLATOR OPTO ISOLATOR I P 21 I P 22 I P 23 I P 24 OPTO ISOLATOR OPTO ISOLATOR...

Page 19: ...NPUTS 13 16 MODULE ADDRESS SWITCH PROCESSOR RS485 COMMS CAN BUS A FROM PREVIOUS MODULE CAN BUS B TO NEXT MODULE LATCH OPEN COLLECTOR OUTPUT 1 OPEN COLLECTOR OUTPUT 2 OPEN COLLECTOR OUTPUT 3 OPEN COLLE...

Page 20: ...8 O Ps Busy Etc Touch Screen Control Fault Reporting 24 I puts f m n ro Fi De c io System F D S re te t n ssage i alisati n Me In ti o 24 CAN BUS B CAT 5 Cable CAN BUS A CAT 5 Cable CAN BUS A Laptop f...

Page 21: ...uts 10 Outputs 2 Reserve Up to 12 Internal Messages Audio Inputs BFM01 Fire Microphone BVR16M Microphone BDM416 Microphone BDM416 Microphone BDM301 Microphone Radio Microphone BVRDFPI BVRDCI 16 I Ps 8...

Page 22: ...VIGIL EVAS BVRD2M Operating Instructions 16 BVRD2M issue 2 C O M M U N I C A T I O N S www acornfiresecurity com www acornfiresecurity com...

Page 23: ...NG SLAVE UNIT S The BVRD2S slave unit s mount directly on top the master unit To minimise rack wiring the power and communications between master and slave units are via an internal data link Figure 2...

Page 24: ...2 Slave on top of Master unit Carefully line up the data link connectors and gently push the two units together Once fitted together fit the four securing screws supplied through the tabs in the slave...

Page 25: ...rehensive Menu Structure is used that depending on the Access Level allows access to all configurable options The front panel controls are used to navigate through the Menu options and also to edit te...

Page 26: ...ess to move right through available menus and options F Select navigation button Press to choose the currently selected option G Back navigation button Press to move back to the previous menu H Status...

Page 27: ...d before the relevant system configuration options are available Table 3 1 Typical Options available to each Access Level Access Level Configuration Command Option 1 2 3 4 5 View all Current Faults La...

Page 28: ...d Right buttons until it is underlined Rotate the Encoder until the required value option etc is displayed To select a sub menu move the cursor using the Left and Right buttons until the first charact...

Page 29: ...an input sensitivity of 80mV 20dB to 3V 12dB Each Audio Input has 3 band parametric plus bass and treble equalisation and an optional limiter compressor Audio Inputs 1 and 2 have a Bypass facility th...

Page 30: ...he maximum output level available is 4 5V 15 5db Each Audio Output has 10 band parametric plus bass and treble equalisation and an optional audio delay The Audio Outputs can be set to be either a Zone...

Page 31: ...d the repeat timer can be set to play the message after the required number of seconds i e an alert message If required multiple message slots upto three adjacent slots subject to configuration restri...

Page 32: ...ditions the evacuate message is stored in flash memory and is accessed by its associated DSP however in the event of DSP failure a separate non processor derived fail safe message will be broadcast to...

Page 33: ...ursor to the Audio option Press Select to enter the Audio Configuration menu then move the cursor to the Outputs option The Audio Outputs menu will now be displayed 2 Select Audio Output 3 using the R...

Page 34: ...tary Encoder to select the required character 9 Continue to enter the required text and when completed press the Rotary Encoder The cursor will return to the Audio Output number and the name change wi...